ANNEX
3
LIST OF ITEMS
TO BE REPORTED TO IAEA
Items marked *
and shaded are prohibited to Iraq under Resolution
687.
The notation (SC II) or (SC IV)
indicates that items of the same type/category are also listed in
one of the Annexes (2 or 4, respectively) of the UN Special Commission
Plan.
NUCLEAR
MATERIALS
1.
Source and special fissionable material as follows:
1.1. Uranium containing the mixture of isotopes occurring in
nature; uranium depleted in the isotope 235; thorium; any of the foregoing
in the form of metal, alloy, chemical compound or concentrate and any
other goods containing one or more of the foregoing.
1.2.
Low Enriched Uranium (LEU), or plutonium as follows:
Uranium
enriched to less than 20% of the isotopes 233, 235, or both; plutonium
with an isotopic concentration of Pu-238 exceeding 80%; any of the foregoing
in the form of metal, alloy, chemical compound or concentrate and any
other goods containing one or more of the foregoing.
1.3.
*Highly Enriched Uranium (HEU) or plutonium, as follows:
Uranium
enriched to 20% or more in isotopes 233, 235, or both; plutonium containing
less than 80% plutonium 238; any of the foregoing in the form of metal,
alloy, chemical compound or concentrate and any other goods containing
one or more of the foregoing except for the following items which
are not prohibited, but are controlled:
Sub-gram amounts of the special fissionable material specified in 1.3
above in the form of:
(a) certified reference material;
(b)
instrument calibration source; or
(c) sensing components in instruments
1.4.
*Irradiated nuclear fuel
EXPLANATORY NOTE:
The
prohibition applies only to the transfer of irradiated nuclear fuel
to Iraq.
NON-NUCLEAR
MATERIALS
2.
Zirconium (SC IV)
2.1. Zirconium metal and alloys in the form of tubes, or assemblies
of tubes, specially designed or prepared for use in a nuclear reactor
and in which the relation of hafnium to zirconium is less than 1:500
parts by weight.
2.2.
Zirconium as follows: metal, alloys containing more than 50%
zirconium by weight, and compounds in which the ratio of hafnium content
to zirconium content is less than 1 part to 500 parts by weight, and
manufactures wholly thereof; except zirconium in the form of foil having
a thickness not exceeding 0.10 mm (0.004 in).
TECHNICAL
NOTE: This
applies to waste and scrap containing zirconium as defined here.
3.
Aluminum alloys
Aluminum
alloys capable of an ultimate tensile strength of 460 MPa (0.46 x 109
N/m2) or more at 293 K (20C), in the form of tubes or solid
forms (including forgings) having an outside diameter or more than 75
mm (3 in).
TECHNICAL
NOTE:
The phrase "capable of" encompasses aluminum alloys before or after
heat treatment.
4.
Fibrous or filamentary materials (SC IV)
4.1. Carbon or aramid fibrous or filamentary materials
having a specific modulus of 12.7 x 10^6 m or greater or a
specific tensile strength of 23.5 x 10^4 m or greater; or
4.2. Glass fibrous or filamentary materials having a specific
modulus of 3.18 x 10^6 m or greater and a specific tensile
strength of 7.62 x 10^4 m or greater;
4.3.
*Composite structures in the form of tubes with an inside diameter of
between 75 mm (3 in) and 400 mm (16 in) made with fibrous or filamentary
materials described in 4.1 and 4.2 above.
TECHNICAL NOTE:
The term "fibrous or filamentary materials" includes continuous
monofilaments, continuous yarns, and tapes;
"Specific
modulus" is the Young's modulus in N/m2 divided by the specific weight
in N/m3 when measured at a temperature of 23�2C and a relative humidity
of 50�5%
"Specific
tensile strength" is the ultimate tensile strength in N/m2 divided
by the specific weight in N/m3 when measured at a temperature of 23�2C
and a relative humidity of 50�5%.
5.
*Maraging steel (SC IV)
Maraging steel capable of an ultimate tensile strength of 2050 MPa (2.050
x 109 N/m2) (300,000 lb/in2) or more
at 293 K (20C) except forms in which no linear dimension exceeds 75 mm
(3 in).
TECHNICAL
NOTE:
The phrase "capable of" encompasses maraging steel before or after heat
treatment.
6.
Titanium
Titanium
alloys capable of an ultimate tensile strength of 900 MPa (0.9 x 109
N/m2) or more at 293 K (20C) in the form of tubes or solid
forms (including forgings) with an outside diameter more than 75 mm (3
in).
TECHNICAL
NOTE:
The phrase "capable of" encompasses titanium alloys before or after heat
treatment.
7.
Chlorine trifluoride (SC IV)
8.
*Fast-reacting ion-exchange resins/adsorbents
Fast-reacting
ion-exchange resins or adsorbents specially designed or prepared for uranium
enrichment using the ion exchange process, including porous macroreticular
resins, and/or pellicular structures in which the active chemical exchange
groups are limited to a coating on the surface of an inactive porous support
structure, and other composite structures in any suitable form including
particles or fibers. These ion exchange resins/adsorbents have diameters
of 0.2 mm or less and must be chemically resistant to concentrated hydrochloric
acid solutions, as well as, physically strong enough so as not to degrade
in the exchange columns. The resins/adsorbents are specially designed
to achieve very fast uranium isotope exchange kinetics (exchange rate
half-time of less than 10 seconds) and are capable of operating at a temperature
in the range of 100C to 200C.
9.
Beryllium (SC IV)
Beryllium
as follows: metal, alloys containing more than 50% of beryllium by weight,
compounds containing beryllium and manufactures thereof; except:
9.1. Metal windows for X-ray machines;
9.2.
Oxide shapes in fabricated or semi-fabricated forms specially
designed for electronic component parts or as substrates for electronic
circuits;
9.3.
Naturally occurring compounds containing beryllium.
TECHNICAL
NOTE:
This entry includes waste and scrap containing beryllium as defined
here.
10.
Calcium
Calcium
metal containing both equal to or less than 0.2% by weight of impurities
other than magnesium and less than 20 ppm of boron.
11.
Magnesium (SC IV)
Magnesium
metal containing both equal to or less than 0.2% by weight of impurities
other than calcium and less than 20 PPM of boron.
12.
Tantalum (SC IV)
Tantalum
sheets with a thickness of 2.5 mm or greater from which a circle of 200
mm diameter can be obtained.
13.
Tungsten, as follows: (SC IV)
Parts
made of tungsten, tungsten carbide, or tungsten alloys (greater than 90%
tungsten) having a mass greater than 20 kg and a hollow cylindrical symmetry
(including cylinder segments) with an inside diameter greater than 100
mm (4 in ) but less than 300 mm
(12 in).
14.
Hafnium
Hafnium
as follows: metal, alloys, and compounds of hafnium containing more than
60% hafnium by weight and manufactures thereof.
15.
Boron
Boron
and boron compounds, mixtures and loaded materials in which the boron-10
isotope is more than 20% by weight of the total boron content.
16.
Bismuth
High
Purity (99.99% or greater) bismuth with very low silver content (less
than 10 parts per million).
17.
Lithium
Isotopically
enriched in lithium-6; as follows:
17.1
*Metal, hydrides or alloys containing lithium enriched in the lithium-6
isotope (6Li) to a concentration higher that the one existing in nature
(7.5% on an atom percentage basis):
17.2.
*Any other materials containing lithium enriched in the lithium-6 isotope
(including compounds, mixtures and concentrates):
17.3.
6Li incorporated in thermoluminescent dosimeters.
18.
*Helium-3
Helium
in any form isotopically enriched in the helium-3 isotope, whether or
not mixed with other materials or contained in any equipment or device,
except for the following items which are not prohibited, but are controlled:
Products or devices containing less than 1 g of helium-3.
19.
Tritium
19.1. *Tritium, including compounds and mixtures, containing
tritium in which the ratio of tritium to hydrogenby atoms exceeds 1
part in 1000.
19.2.
Tritium in luminescent devices (e.g. safety devices installed in aircraft,
watches, runway lights) containing more than 40 Ci of tritium in any
chemical or physical form.
19.3.
Tritium labeled organic compounds
20.
Deuterium and heavy water
Deuterium,
heavy water (deuterium oxide) and any other deuterium compound in which
the ratio of deuterium to hydrogen atoms exceeds 1:5000 for use in a nuclear
reactor.
21.
Nuclear grade graphite
Graphite
having a purity level better than 5 parts per million boron equivalent
and with a density greater than 1.50 g/cm^3.
*
PLANTS FOR THE SEPARATION OF ISOTOPES OF URANIUM AND EQUIPMENT, OTHER
THAN ANALYTICAL INSTRUMENTS, SPECIALLY DESIGNED OR PREPARED THEREFOR
Items
of equipment that are considered to fall within the meaning of the phrase
"equipment other than analytical instruments, specially designed or prepared"
for the separation of isotopes of uranium include:
22.
*Gas centrifuges and assemblies and components specially designed or prepared
for use in gas centrifuges
INTRODUCTORY NOTE
The gas centrifuge normally consists of a thin-walled cylinder(s) of between
75 mm (3 in) and 400 mm (16 in) diameter contained in a vacuum environment
and spun at high peripheral speed of the order of 300 m/s or more with
its central axis vertical. In order to achieve high speed, the materials
of construction for the rotating components have to be of a high strength
to density ratio and the rotor assembly, and hence its individual components
have to be manufactured to very close tolerances in order to minimize
the imbalance. In contrast to other centrifuges, the gas centrifuge for
uranium enrichment is characterized by having, within the rotor chamber,
a rotating disc-shaped baffle(s) and a stationary tube arrangement for
feeding and extracting the UF6 gas and featuring at least 3
separate channels, of which 2 are connected to scoops extending from the
rotor axis towards the periphery of the rotor chamber. Also contained
within the vacuum environment are a number of critical items which do
not rotate and which, although they are specially designed, are not difficult
to fabricate, nor are they fabricated out of unique materials. A centrifuge
facility, however, requires a large number of these components, so that
quantities can provide an important indication of end use.
22.1. *Rotating components
(a)
Complete rotor assemblies: Thin-walled cylinders (or a number
of interconnected thin-walled cylinders) manufactured from one or
more of the high strength to density ratio materials described in
the explanatory note to this section. If interconnected, the cylinders
are joined together by flexible bellows or rings as described in section
(c) following. The rotor is fitted with an internal baffle(s) and
end caps, as described in section (d) and (e) following, if in final
form. However, the complete assembly may be delivered only partly
assembled.
(b)
Rotor tubes: Specially designed or prepared thin-walled cylinders
with thickness of 12 mm (0.5 in) or less, a diameter of between 75
mm (3 in) and 400 mm (16 in), and manufactured from one or more of
the high strength to density ratio materials described in the explanatory
note to this section.
(c)
Rings or bellows: Components specially designed or prepared
to give localized support to the rotor tube or to join together a
number of rotor tubes. The bellows is a short cylinder of wall thickness
3 mm (0.12 in) or less, a diameter of between 75 mm (3 in) and 400
mm (16 in), having a convolute and manufactured from one or more of
the high strength to density ratio materials described in the explanatory
note to this section.
(d)
Baffles: Disc-shaped components of between 75 mm (3 in) and
400 mm (16 in) in diameter specially designed or prepared to be mounted
inside the centrifuge rotor tube, in order to isolate the take-off
chamber from the main separation chamber and, in some cases, to assist
the UF6 gas circulation within the main separation chamber
of the rotor tube, and manufactured from one or more of the high strength
to density ratio materials described in the explanatory note to this
section.
(e)
Top caps/Bottom caps: Disc-shaped components of between 75
mm (3 in) and 400 mm (16 in) in diameter specially designed or prepared
to fit to the ends of the rotor tube, and so contain the UF6
within the rotor tube, and in some cases to support, retain, or contain
as an integrated part an element of the upper bearing (top cap) or
to carry the rotating elements of the motor and lower bearing (bottom
cap), and manufactured from one of the high strength to density ratio
materials described in the explanatory notes to this section.
EXPLANATORY
NOTE:
The materials used for centrifuge rotating components are: Maraging
steel capable of an ultimate tensile strength of 2.05 x 109
N/m2 (300,000 psi) or more; Aluminum alloys capable of
an ultimate tensile strength of 0.46 x 109 N/m2
(67,000 psi) or more; Filamentary materials suitable for use in composite
structures and having a specific modulus of 12.3 x 106
m or greater and a specific ultimate tensile strength of 0.3 x 106
m or greater ('Specific Modulus' is the 'Young Modulus in N/m2
divided by the specific weight in N/m3; 'Specific
Ultimate Tensile Strength' is the ultimate tensile strength in N/m2
divided by the specific weight in N/m3.)
22.2. *Static components
(a) Magnetic suspension bearings:
Specially designed or prepared bearing assemblies consisting of an
annular magnet suspended within a housing containing a damping medium.
The housing is manufactured from a UF6-resistant material
(see explanatory note to Section 23). The magnet couples with a pole
piece or a second magnet fitted to the top cap described in Section
22.1.(e). The magnet may be ring-shaped with a relation between the
outer and inner diameter smaller or equal to 1.6:1. The magnet may
be in a form having an initial permeability of 0.15 H/m (120,000 in
CGS units) or more, or a remanence of 98.5% or more, or an energy
product of greater than 80 kJ/m3 (107 gauss-oersteds).
In addition to the usual material properties, it is a prerequisite
that the deviation of the magnetic axes from the geometrical axes
is limited to very small tolerances (lower than 0.1 mm or 0.004 in)
or that homogeneity of the material of the magnet is specially called
for.
(b)
Bearings/Dampers:
Specially designed or prepared bearings comprising a pivot/cup assembly
mounted on a damper. The pivot is normally a hardened steel shaft
with a hemisphere at one end with a means of attachment to the bottom
cap described in Section 22.1.(e) at the other. The shaft may, however,
have a hydrodynamic bearing attached. The cup is pellet-shaped with
a hemispherical indentation in one surface. These components are often
supplied separately to the damper.
(c)
Molecular pumps:
Specially designed or prepared cylinders having internally machined
or extruded helical grooves and internally machined bores. Typical
dimensions are as follows: 75 mm (3 in) to 400 mm (16 in) internal
diameter, 10 mm (0.4 in) or more wall thickness, with the length equal
to or greater than the diameter. The grooves are typically rectangular
in cross-section and 2 mm (0.08 in) or more in depth.
(d)
Motor stators:
Specially designed or prepared ring-shaped stators for high-speed
multiphase AC hysteresis (or reluctance) motors for synchronous operation
within a vacuum in the frequency range of 600-2000 Hz and a power
range of 50 -1000 VA. The stators consist of multi-phase windings
on a laminated low loss iron core comprised of thin layers typically
2.0 mm (0.08 in) thick or less.
(e)
Centrifuge housing/recipients:
Components specially designed or prepared to contain the rotor tube
assembly of a gas centrifuge. The housing consists of a rigid cylinder
of wall thickness up to 30 mm (1.2 in) with precision machined ends
to locate the bearings and with one or more flanges for mounting.
The machined ends are parallel to each other and perpendicular to
the cylinder's longitudinal axis to within 0.05 degrees or less. The
housing may also be a honeycomb type structure to accommodate several
rotor tubes. The housings are made of, or protected by, materials
resistant to corrosion by UF6.
(f)
Scoops:
Specially designed or prepared tubes of up to 12 mm (0.5 in) internal
diameter for the extraction of UF6 gas from within the
rotor tube by a Pitot tube action (that is, with an aperture facing
into the circumferential gas flow within the rotor tube, for example
by bending the end of a radially disposed tube) and capable of being
fixed to the central gas extraction system. The tubes are made of,
or protected by, materials resistant to corrosion by UF6.
23.
*Specially designed or prepared auxiliary systems, equipment and, components
for gas centrifuge enrichment plants
INTRODUCTORY NOTE
The auxiliary systems, equipment, and components for a gas centrifuge
enrichment plant are the systems of the plant needed to feed UF6
to the centrifuges, to link the individual centrifuge to each other to
form cascades (or stages) to allow for progressively higher enrichments
and to extract the 'product' and 'tails' UF6 from the centrifuge
together with the equipment required to drive the centrifuges or to control
the plant. Normally, UF6 is evaporated from the solid using
heated autoclaves and is distributed in gaseous form to the centrifuge
by way of cascade header pipework. The 'product' and 'tails' UF6
gaseous streams flowing from the centrifuge are also passed by way of
cascade header pipework to cold traps (operating at about 203 K (-70oC))
where they are condensed prior to onward transfer into suitable containers
for transportation or storage. Because an enrichment plant consists of
many thousands of centrifuges arranged in cascades there are many kilometers
of cascade header pipework, incorporating thousands of welds with a substantial
amount of repetition of layout. The equipment, components and piping systems
are fabricated to very high vacuum and cleanliness standards.
23.1. *Feed systems/'product' and 'tails' withdrawal systems
Specially
designed or prepared process systems including:
(a)
Feed autoclaves (or stations) used for passing UF6
to the centrifuge cascades at up to 100 kPa (15 psi) and at a rate
of 1 kg/h or more;
(b)
Desublimers (or cold traps) used to remove
UF6 from the cascades at up to 3 kPa (0.5 psi) pressure.
The desublimers are capable of being chilled to 203 K (-70C) and heated
to 343 K (70C); and
(c)
'Product' and 'tails' stations used for trapping UF6
into containers
This plant, equipment, and pipework is wholly made of or lined with
UF6-resistant materials (see explanatory note at the end
of this section) and is, fabricated to very high vacuum and cleanliness
standards.
23.2. *Machine header piping systems
Specially designed or prepared piping systems and header systems for handling
UF6 within the centrifuge cascades. The piping network is normally
of the 'triple' header system with each centrifuge connected to each of
the headers. There is, thus, a substantial amount of repetition in its
form. It is wholly made of UF6-resistant materials (see explanatory
note at the end of this section) and is fabricated to very high vacuum
and cleanliness standards.
23.3. *UF6 Mass spectrometers/mass ion sources
Specially designed or prepared magnetic or quadrupole mass spectrometers,
capable of taking 'on-line' samples of feed, 'product' or 'tails',
from UF6 gas streams and having all of the following characteristics:
(a)
Unit resolution for atomic mass unit greater than 320;
(b)
Ion sources constructed of or lined with nichrome or monel
or nickel plated;
(c)
Electron bombardment ionization sources; and
(d)
A collector system suitable for isotopic analysis.
23.4
*Frequency
changers
Frequency changers (also known as converters or invertors) specially
designed or prepared to supply motor stators as defined under 22.2.(d),
or parts, components, and sub-assemblies of such frequency changers
having all of the following characteristics:
(a)
A multiphase output of 600 to 2000 Hz;
(b)
High stability (with frequency control better than 0.1%);
and
(c)
Total harmonic distortion less than 2%.
EXPLANATORY
NOTE:
The items listed in section 23 either come into direct contact with the
UF6 process gas or directly control the centrifuges and the
passage of the gas from centrifuge to centrifuge and cascade to cascade.
Materials resistant to corrosion by UF6 include stainless steel,
aluminum, aluminum alloys, nickel, or alloys containing 60% or more nickel.
24.
*Specially designed or prepared assemblies and components for use in gaseous
diffusion enrichment
INTRODUCTORY
NOTE
In the gaseous diffusion method of uranium isotope separation, the main
technological assembly is a special porous gaseous diffusion barrier,
heat exchanger for cooling the gas (which is heated by the process of
compression), seal valves and control valves, and pipelines. In as much
as gaseous diffusion technology uses uranium hexafluoride (UF6 ),
all equipment, pipeline and instrumentation surfaces (that come in contact
with the gas) must be made of materials that remain stable in contact
with UF6 . A gaseous diffusion facility requires a number of
these assemblies, so that quantities can provide an important indication
of end use.
24.1. * Gaseous diffusion barriers
(a) Specially designed or prepared thin, porous filters, with
a pore size of 100 - l000 Å (ångstroms), a thickness
of 5 mm (0.2 in) or less, and for tubular forms, a diameter of 25
mm (1 in) or less, made of metallic, polymer or ceramic materials
resistant to corrosion by UF6, and
(b) Specially
prepared compounds or powders for the manufacture of such filters.
Such compounds and powders include nickel or alloys containing 60%
or more nickel, aluminum oxide, or UF6-resistant fully
fluorinated hydrocarbon polymers having a purity of 99.9% or more,
a particle size less than 10 microns, and a high degree of particle
size uniformity, which are specially prepared for the manufacture
of gaseous diffusion barriers.
24.2. *Diffuser housings
Specially
designed or prepared hermetically sealed cylindrical vessels greater
than 300 mm (12 in) in diameter and greater than 900 mm (35 in) in length,
or rectangular vessels of comparable dimensions, which have an inlet
connection and two outlet connections all of which are greater than
50 mm (2 in) in diameter, for containing the gaseous diffusion barrier,
made of or lined with UF6-resistant materials and designed
for horizontal or vertical installation.
24.3.
*Compressors and gas blowers
Specially
designed or prepared axial, centrifugal, or positive displacement compressors,
or gas blowers with a suction volume capacity of 1 m3/min
or more of UF6, and with a discharge pressure of up to several
hundred kPa (100 psi), designed for long-term operation in the UF6
environment with or without an electrical motor of appropriate power,
as well as separate assemblies of such compressors and gas blowers.
These compressors and gas blowers have a pressure ratio between 2:1
and 6:1 and are made of, or lined with, materials resistant to UF6.
24.4.
*Rotary shaft seals
Specially
designed or prepared vacuum seals, with seal feed and seal exhaust connections,
for sealing the shaft connecting the compressor or the gas blower rotor
with the driver motor, so as to ensure a reliable seal against in-leaking
of air into the inner chamber of the compressor or gas blower which
is filled with UF6. Such seals are normally designed for
a buffer gas in-leakage rate of less than 1000 cm^3/min (60
in^3/min).
24.5.
*Heat exchangers for cooling UF6
Specially
designed or prepared heat exchangers made of or lined with UF6-resistant
materials (except stainless steel) or with copper or any combination
of those metals, and intended for a leakage pressure change rate of
less than 10 Pa (0.0015 psi) per hour under a pressure difference of
100 kPa (15 psi).
25.
*Specially designed or prepared auxiliary systems, equipment and components
for use in gaseous diffusion enrichment
INTRODUCTORY
NOTE
The auxiliary systems, equipment and components for gaseous diffusion
enrichment plants are the systems of plant needed to feed UF6
to the gaseous diffusion assembly, to link the individual assemblies to
each other to form cascades (or stages) to allow for progressively higher
enrichments and to extract the 'product' and 'tails' UF6 from
the diffusion cascades. Because of the high inertial properties of diffusion
cascades, any interruption in their operation, and specially their shut-down,
leads to serious consequences. Therefore, a strict and constant maintenance
of vacuum in all technological systems, automatic protection from accidents,
the precise automated regulation of the gas flow is of importance in a
gaseous diffusion plant. All this leads to a need to equip the plant with
a large number of special measuring, regulating and controlling systems.
Normally, UF6 is evaporated from cylinders placed within autoclaves
and is distributed in gaseous form to the entry point by way of cascade
header pipework. The 'product' and 'tails' UF6 gaseous streams
flowing from exit points are passed by way of cascade header pipework
to either cold traps or to compression stations where the UF6
gas is liquefied prior to onward transfer into suitable containers for
transportation or storage. Because a gaseous diffusion enrichment plant
consists of a large number of gaseous diffusion assemblies arranged in
cascades, there are many kilometers of cascade header pipework, incorporating
thousands of welds with substantial amounts of repetition of layout. The
equipment, components and piping systems are fabricated to very high vacuum
and cleanliness standards.
25.1.
*Feed systems/'product' and 'tails' withdrawal systems
Specially designed or prepared process systems, capable of operating
at pressures of 300 kPa (45 psi) or less, including:
(a) Feed autoclaves, or systems used for passing
UF6 to the gaseous diffusion cascade;
(b) Desublimers (or cold traps)used to remove UF6
from diffusion cascades;
(c) Liquefaction stations where UF6 gas
from the cascade is compressed and cooled to form liquid UF6;
and
(d) 'Product' or 'tails' stations used for transferring
UF6 into containers.
25.2.
*Header piping systems
Specially designed or prepared piping systems and header systems, for
handling UF6 within the gaseous diffusion cascade. This piping
network is normally of the 'double' header system with each stage or
group of stages connected to each of the headers.
25.3.
*Vacuum systems
(a) Specially designed or prepared large vacuum manifolds,
vacuum headers and vacuum pumps having a suction capacity of 5 m3/min
(175 ft3 / min) or more; and
(b)
Vacuum pumps specially designed for service in UF6-bearing
atmospheres made of, or lined with, aluminum, nickel, or alloys bearing
more than 60% nickel. These pumps may be either rotary or positive,
may have displacement and fluorocarbon seals, and may have special
working fluids present.
25.4.
*Special shut-off and control valves
Specially
designed or prepared manual or automated shut-off and control bellows
valves made of UF6-resistant materials with a diameter of
40 to 1500 mm (1.5 to 59 in) for installation in main and auxiliary
systems of gaseous diffusion enrichment plants.
25.5.
*UF6 mass spectrometers/ion sources
Specially
designed or prepared magnetic or quadrupole mass spectrometers capable
of taking "on-line" samples of feed, 'product' or 'tails', from UF6
gas streams and having all of the following characteristics:
(a)
Unit resolution for atomic mass unit greater than 320;
(b)
Ion sources constructed of or lined with nichrome or monel
or nickel plated;
(c)
Electron bombardment ionization sources; and
(d)
Collector system suitable for isotopic analysis.
EXPLANATORY
NOTE:
The items listed in section 25 above either come into direct contact
with the UF6 process gas or directly control the flow within
the cascade. All surfaces which come into contact with the process gas
are wholly made of, or lined with, UF6-resistant materials.
For the purposes of the sections relating to gaseous diffusion items,
the materials resistant to corrosion by UF6 include stainless
steel, aluminum, aluminum alloys, aluminum oxide, nickel or alloys containing
60% or more nickel and UF6-resistant fully fluorinated hydrocarbon
polymers.
26.
Specially designed or prepared systems, equipment and components for use
in aerodynamic enrichment plants
INTRODUCTORY
NOTE
In aerodynamic enrichment processes, a mixture of gaseous UF6
and light gas (hydrogen or helium) is compressed and then passed through
separating elements wherein isotopic separation is accomplished by the
generation of high centrifugal forces over a curved-wall geometry. Two
processes of this type have been successfully developed: the separation
nozzle process and the vortex tube process. For both processes, the main
components of a separation stage include cylindrical vessels housing the
special separation elements (nozzle or vortex tubes), gas compressors,
and heat exchangers to remove the heat of compression. An aerodynamic
plant requires a number of these stages, so that quantities can provide
an important indication of end use. Since aerodynamic processes use UF6
, all equipment, pipeline and instrumentation surfaces (that come
in contact with the gas) must be made of materials that are stable in
contact with UF6.
EXPLANATORY
NOTE:
The items listed in this section either come into direct contact with
the UF6 process gas or directly control the flow within the
cascade. All surfaces which come into contact with the process gas are
wholly made of, or protected by, UF6-resistant materials. For
the purposes of the section relating to aerodynamic enrichment items,
the materials resistant to corrosion by UF6 include copper,
stainless steel, aluminum, aluminum alloys, nickel or alloys containing
60% or more nickel and UF6-resistant fully fluorinated hydrocarbon
polymers.
26.1.
*Separation nozzles
Specially
designed or prepared separation nozzles and assemblies thereof. The
separation nozzles consist of slit-shaped, curved channels having a
radius of curvature less than 1 mm (typically 0.1 to 0.05 mm), resistant
to corrosion by UF6 and having a knife-edge within the nozzle
that separates the gas flowing through the nozzle into two fractions.
26.2.
*Vortex tubes
Specially
designed or prepared vortex tubes and assemblies thereof. The vortex
tubes are cylindrical or tapered, made of, or protected by, materials
resistant to corrosion by UF6, having a diameter of between
0.5 cm and 4 cm, a length to diameter ratio of 20:1 or less and with
one or more tangential inlets. The tubes may be equipped with nozzle-type
appendages at either or both ends.
EXPLANATORY
NOTE:
The feed gas enters the vortex tube tangentially at one end or through
swirl vanes or at numerous tangential positions along the periphery
of the tube.
26.3.
*Compressors and gas blowers
Specially
designed or prepared axial, centrifugal or positive displacement compressors
or gas blowers made of, or protected by, materials resistant to corrosion
by UF6 and with a suction volume capacity of 2 m3/min
or more of UF6/carrier gas (hydrogen or helium) mixture.
EXPLANATORY
NOTE:
These compressors and gas blowers typically have a pressure ratio between
1.2:1 and 6:1.
26.4.
*Rotary shaft seals
Specially
designed or prepared rotary shaft seals, with seal feed and seal exhaust
connections, for sealing the shaft connecting the compressor rotor or
the gas blower rotor with the driver motor so as to ensure a reliable
seal against out-leakage of process gas or in-leakage of air or seal
gas into the inner chamber of the compressor or gas blower which is
filled with a UF6/carrier gas mixture.
26.5.
*Heat exchangers for gas cooling
Specially
designed or prepared heat exchangers made of, or protected by, materials
resistant to corrosion by UF6.
26.6.
*Separation element housings
Specially
designed or prepared separation element housings, made of, or protected
by, materials resistant to corrosion by UF6, for containing
vortex tubes or separation nozzles.
EXPLANATORY
NOTE:
These housings may be cylindrical vessels greater than 300 mm in diameter
and greater than 900 mm in length or may be rectangular vessels of comparable
dimensions, and may be designed for horizontal or vertical installation.
26.7.
*Feed systems/'product' and 'tails' withdrawal systems
Specially
designed or prepared process systems or equipment for enrichment plants
made of, or protected by, materials resistant to corrosion by UF6,
including:
(a) Feed
autoclaves, ovens, or systems used for passing UF6 to the
enrichment process;
(b)
Desublimers (or cold traps) used to remove UF6
from the enrichment process for subsequent transfer upon heating;
(c)
Solidification or liquefaction stations used to remove UF6
from the enrichment process by compressing and converting UF6
to a liquid or solid form; and
(d)
'Product' or 'tails' stations used for transferring UF6
into containers
26.8.
*Header piping systems
Specially
designed or prepared header piping systems, made of, or protected by,
materials resistant to corrosion by UF6, for handling UF6
within the aerodynamic cascades. This piping network is normally of
the 'double' header design with each stage or group of stages connected
to each of the headers.
26.9.
*Vacuum systems and pumps
(a) Specially designed or prepared vacuum systems having a
suction capacity of 5 m^3/min or more, consisting of vacuum
manifolds, vacuum headers and vacuum pumps, and designed for service
in UF6 bearing atmospheres; and
(b)
Vacuum pumps specially designed or prepared for service in
UF6-bearing atmospheres and made of, or protected by, materials
resistant to corrosion by UF6. These pumps may use fluorocarbon
seals and special working fluids.
26.10.
*Special shut-off and control valves
Specially
designed or prepared manual or automated shutoff and control bellows
valves made of, or protected by, materials resistant to corrosion by
UF6 with a diameter of 40 to 1500 mm for installation in
main and auxiliary systems of aerodynamic enrichment plants.
26.11.
*UF6 mass spectrometers/ion sources
Specially
designed or prepared magnetic or quadrupole mass spectrometers capable
of taking 'on-line' samples of feed, 'product' or 'tails', from UF6
gas streams and having all of the following characteristics:
(a)
Unit
resolution for mass greater than 320;
(b)
Ion sources constructed of or lined with nichrome or monel
or nickel plated;
(c)
Electron bombardment ionization sources; and
(d)
Collector system suitable for isotopic analysis.
26.12.
*UF6/carrier gas separation systems
Specially
designed or prepared process systems for separating UF6 from
carrier gas (hydrogen or helium).
EXPLANATORY
NOTE:
These systems are designed to reduce the UF6 content in the
carrier gas to 1 PPM or less, and may incorporate equipment such as:
cryogenic heat exchangers and cryoseparators capable of temperatures
of -120oC or less, or
cryogenic
refrigeration units capable of temperatures of -120oC or
less, or
separation
nozzle or vortex tube units for the separation of UF6 from
carrier gas, or
UF6
cold traps capable of temperatures of -20oC or less.
27.
*Specially designed or prepared systems, equipment and components for
use in chemical exchange or ion exchange enrichment plants.
INTRODUCTORY
NOTE
The slight difference in mass between the isotopes of uranium causes small
changes in chemical reaction equilibria that can be used as a basis for
separation of the isotopes. Two processes have been successfully developed:
liquid-liquid chemical exchange and solid-liquid ion exchange.
In
the liquid-liquid chemical exchange process, immiscible liquid phases
(aqueous and organic) are countercurrently contacted to give the cascading
effect of thousands of separation stages. The aqueous phase consists of
uranium chloride in hydrochloric acid solution. The organic phase consists
of an extractant containing uranium chloride in an organic solvent. The
contactors employed in the separation cascade can be liquid-liquid exchange
columns (such as pulsed columns with sieve plates) or liquid centrifugal
contactors. Chemical conversions (oxidation and reduction) are required
at both ends of the separation cascade in order to provide for the reflux
requirement at each end. A major design concern is to avoid contamination
of the process streams with certain metal ions. Plastic, plastic-lined
(including use of fluorocarbon polymers) and/or glass-lined columns and
piping are therefore used.
In
the solid-liquid ion-exchange process, enrichment is accomplished by uranium
adsorption/desorption on a special very fast-acting, ion-exchange resin
or adsorbent. A solution of uranium in hydrochloric acid and other chemical
agents is passed through cylindrical enrichment columns containing packed
beds of the adsorbent. For a continuos process, a reflux system is necessary
to release the uranium from the adsorbent back into the liquid flow so
that 'products' and 'tails' can be collected. This is accomplished with
the use of suitable reduction/oxidation chemical agents that are fully
regenerated in separate external circuits and that may be partly regenerated
within the isotopic separation columns themselves.. The presence of hot
concentrated hydrochloric acid solutions in the process requires that
the equipment be made of, or protected by, special corrosion-resistant
materials.
27.1.
*Liquid-liquid exchange columns (Chemical exchange)
Countercurrent
liquid-liquid exchange columns having mechanical power input (i.e.,
pulsed columns with sieve plates, reciprocating plate columns, and columns
with internal turbine mixers), specially designed or prepared for uranium
enrichment using the chemical exchange process. For corrosion resistance
to concentrated hydrochloric acid solutions, these columns and their
internals are made of, or protected by, suitable plastic materials (such
as fluorocarbon polymers) or glass. The stage residence time of the
columns is designed to be short (30 seconds or less).
27.2.
*Liquid-liquid centrifugal contactors (Chemical exchange)
Liquid-liquid
centrifugal contactors specially designed or prepared for uranium enrichment
using the chemical exchange process. Such contactors use rotation to
achieve dispersion of the organic and aqueous streams and then centrifugal
force to separate the phases. For corrosion resistance to concentrated
hydrochloric acid solutions, the contactors are made of or are lined
with suitable plastic materials (such as fluorocarbon polymers) or are
lined with glass. The stage residence time of the centrifugal contactors
is designed to be short (30 seconds or less).
27.3.
*Uranium reduction systems and equipment (Chemical exchange)
(a) Specially designed or prepared electrochemical reduction
cells to reduce uranium from one valence state to
another for uranium enrichment using the chemical exchange process.
The cell materials in contact with process solutions must be corrosion
resistant to concentrated hydrochloric acid solutions.
EXPLANATORY
NOTE:
The cell cathodic compartment must be designed to prevent re-oxidation
of uranium to its higher valence state. To keep the uranium in the
cathodic compartment, the cell may have an impervious diaphragm membrane
constructed of special cation exchange material. The cathode consists
of a suitable solid conductor such as graphite.
(b)
Specially designed or prepared systems at the product end
of the cascade for taking the U+4 out of the organic stream,
adjusting the acid concentration and feeding to the electrochemical
reduction cells.
EXPLANATORY
NOTE:
These systems consist of solvent extraction equipment for stripping
the U+4 from the organic stream into an aqueous solution,
evaporation and/or other equipment to accomplish solution pH adjustment
and control, and pumps or other transfer devices for feeding to the
electrochemical reduction cells. A major design concern is to avoid
contamination of the aqueous stream with certain metal ions. Consequently
for those parts in contact with the process stream, the system is
constructed of equipment made of, or protected by, suitable materials
(such as glass, fluorocarbon polymers, polyphenyl sulfate, polyether
sulfone, and resin-impregnated graphite).
27.4.
*Feed preparation systems (Chemical exchange)
Specially
designed or prepared systems for producing high-purity uranium chloride
feed solutions for chemical exchange uranium isotope separation plants.
EXPLANATORY
NOTE:
These systems consist of dissolution, solvent extraction and/or ion
exchange equipment for purification and electrolytic cells for reducing
the uranium U+6 or U+4 to U+3. These
systems produce uranium chloride solutions having only a few parts per
million of metallic impurities such as chromium, iron, vanadium, molybdenum
and other bivalent or higher multi-valent cations. Materials of construction
for portions of the system processing high-purity U+3 include
glass, fluorocarbon polymers, polyphenyl sulfate or polyether sulfone
plastic-lined and resin-impregnated graphite
27.5.
*Uranium oxidation systems (Chemical exchange)
Specially
designed or prepared systems for oxidation of U+3
to U+4 for return to the uranium isotope separation cascade
in the chemical exchange enrichment process.
EXPLANATORY
NOTE:
These systems may incorporate equipment such as:
Equipment for contacting chlorine and oxygen with the aqueous effluent
from the isotope separation equipment and extracting the resultant
U+4 into the stripped organic stream returning from the
product end of the cascade; and.
Equipment
that separates water from hydrochloric acid so that the water and
the concentrated hydrochloric acid may be reintroduced to the process
at the proper location.
27.6.
*Ion exchange columns (Ion exchange)
Cylindrical
columns greater than 1000 mm in diameter for containing and supporting
packed beds of ion exchange resin/adsorbent, specially designed or prepared
for uranium enrichment using the ion exchange process. These columns
are made of, or protected by, materials (such as titanium or fluorocarbon
plastics) resistant to corrosion by concentrated hydrochloric acid solutions
and are capable of operating at a temperature in the range of 100C to
200C and pressures above 0.7 MPa (102 psi). See also item 8 for
ion exchange resins/adsorbents.
27.7.
*Ion exchange reflux systems (Ion exchange)
(a) Specially designed or prepared chemical or electrochemical
reduction systems for regeneration of the chemical reducing agent(s)
used in ion exchange uranium enrichment cascades; and
(b)
Specially designed or prepared chemical or electrochemical
oxidation systems for regeneration of the chemical oxidizing agent(s)
used in ion exchange uranium enrichment cascades.
EXPLANATORY
NOTE:
The ion exchange enrichment process may use, for example, trivalent
titanium (Ti+3) as a reducing action in which case the reduction
system would regenerate Ti+3 by reducing Ti+4.
The
process may use for example trivalent iron (Fe+3) as an oxidant
in which case the oxidation system would regenerate Fe+3
by oxidizing Fe+2.
28.
* Specially designed or prepared systems, equipment and components for
use in laser based enrichment plants
INTRODUCTORY
NOTE
Present systems for enrichment processes using laser fall into two categories:
those in which the process medium is atomic uranium vapor and those in
which the process medium is the vapor of a uranium compound. Common nomenclature
for such processes include:
first category - atomic vapor laser isotope separation (AVLIS or SILVA);
second
category - molecular laser isotope separation (MLIS or MOLIS); and
chemical
reaction by isotope selective laser (CRISLA).
The
systems, equipment and components for laser enrichment plants embrace:
devices to feed uranium metal vapor (for selective photo ionization)
or devices to feed the vapor of a uranium compound (for photo-dissociation
or chemical activation);
devices
to collect enriched and depleted uranium metals as 'product' and 'tails'
in the first category, and devices to collect dissociated or reacted
compounds as 'products' and unaffected material as 'tails' in the second
category;
(i)
process laser systems to selectively excite the uranium-235 species;
and
feed
preparation and product conversion equipment.
The
complexity of the spectroscopy of uranium atoms and compounds may require
incorporation of any of a number of available laser technologies.
EXPLANATORY
NOTE:
Many of the items listed in this section come into direct contact with
uranium metal vapor or liquid or with process gas consisting of UF6
or a mixture of UF6 and other gases. All surfaces that come
into contact with the uranium or UF6 are wholly made of, or
protected by, corrosion-resistant materials. For the purposes of the section
relating to laser-based enrichment items, the materials resistant to corrosion
by vapor or liquid uranium metal or uranium alloys include yttria-coated
graphite and tantalum; and the materials resistant to corrosion by UF6
include copper, stainless steel, aluminum, , aluminum alloys, nickel or
alloys containing 60% or more nickel and UF6-resistant fully
fluorinated hydrocarbon polymers.
28.1.
*Uranium vaporization systems (AVLIS)
Specially
designed or prepared uranium vaporization systems which contain high-power
strip or scanning electron beam guns with a delivered power on the target
of more than 2.5 kW/cm.
28.2.
*Liquid uranium metal handling systems (AVLIS)
Specially
designed or prepared liquid metal handling systems for molten uranium
or uranium alloys, consisting of crucibles and cooling equipment for
the crucibles.
EXPLANATORY
NOTE:
The crucibles and other parts of this system that come into contact
with molten uranium or uranium alloy are made of, or protected by, material
of suitable corrosion and heat resistance. Suitable materials include
tantalum, yttria-coated graphite, graphite coated with other rare earth
oxides or mixtures thereof.
28.3.
*Uranium metal 'product' and 'tails' collector assemblies (AVLIS)
Specially
designed or prepared 'product' and 'tails' collector assemblies for
uranium metal in liquid or solid form.
EXPLANATORY
NOTE:
Components for these assemblies are made of, or protected by, materials
resistant to the heat and corrosion of uranium metal vapor or liquid
(such as yttria-coated graphite or tantalum) and may include pipes,
valves, fittings, 'gutters', feed-throughs, heat exchangers and collector
plates for magnetic, electrostatic (or other) separation methods.
28.4.
*Separator module housings (AVLIS)
Specially
designed or prepared cylindrical or rectangular vessels for containing
the uranium metal vapor source, the electron beam gun and the 'product'
and 'tails' collectors.
EXPLANATORY
NOTE:
These housings have multiplicity of ports for electrical and water feed-throughs,
laser beam windows, vacuum pump connections and instrumentation diagnostics
and monitoring. They have provisions for opening and disclosure to allow
refurbishment of internal components.
28.5.
*Supersonic expansion nozzles (MLIS)
Specially
designed or prepared supersonic expansion nozzles for cooling mixtures
of UF6 and carrier gas to 150 K or less and which are corrosion
resistant to UF6.
28.6.
*Uranium pentaflouride product collectors (MLIS)
Specially
designed or prepared uranium pentafluoride (UF5) solid product
collectors consisting of filter, impact or cyclone-type collectors,
or combinations thereof, and which are corrosion resistant to the UF5/UF6
environment.
28.7.
*UF6/carrier gas compressors (MLIS)
Specially
designed or prepared compressors for UF6 carrier gas mixtures,
designed for long term operation in a UF6 environment. The
components of these compressors that come into contact with process
gas are made of, or protected by, materials resistant to corrosion by
UF6.
28.8.
*Rotary shaft seals (MLIS)
Specially
designed or prepared rotary shaft seals, with seal feed and seal exhaust
connections, for sealing the shaft connecting the compressor rotor with
the driver motor so as to ensure a reliable seal against out-leakage
of process gas or in-leakage of air or seal gas into the inner chamber
of the compressor which is filled with a UF6 carrier gas
mixture.
28.9.
*Flourination systems (MLIS)
Specially
designed or prepared systems for fluorinating UF5 (solid)
to UF6 (gas).
EXPLANATORY
NOTE:
These systems are designed to fluorinate the collected UF5
powder to UF6 for subsequent collection in 'product' containers
or for transfer as feed to MLIS units for additional enrichment. In
one approach the fluorination reaction may be accomplished within the
isotopic separation system to react and recover directly off the 'product'
collectors. In another approach, the UF5 powder may be removed/transferred
from the 'product' collectors into a suitable reaction vessel (e.g.,
fluidized-bed reactor, screw reactor or flame tower) for fluorination.
In both approaches, equipment for storage and transfer of fluorine (or
other suitable fluorinating agents) and for collection and transfer
of UF6 are used.
28.10.
*UF6 mass spectrometers/ion sources (MLIS)
Specially
designed or prepared magnetic or quadrupole mass spectrometers capable
of taking 'on-line' samples of feed, 'product' or 'tails', from UF6
gas streams and having all the following characteristics:
(a) Unit resolution for mass greater than 320;
(b)
Ion sources constructed of or lined with nichrome or monel
or nickel plated;
(c)
Electron bombardment ionization sources; and; and;;;;;;;;;;l;
(d)
Collector system suitable for isotopic analysis.
28.11
*Feed systems/'product' and 'tails' withdrawal systems (MLIS)
Specially
designed or prepared process systems or equipment for enrichment plants
made of, or protected by, materials resistant to corrosion by UF6
including:
(a) Feed autoclaves, ovens, or systems used for passing UF6
to the enrichment process;
(b)
Desublimers (or cold traps) used to remove
UF6 from the enrichment process for subsequent transfer
upon heating;
(c)
Solidification or liquefaction stations used to remove UF6
from the enrichment process by compressing and converting UF6
to a liquid or solid form; and
(d)
'Product' or 'tails' stations used for transferring UF6
into containers.
28.12.
*UF6/carrier gas separation systems
Specially
designed or prepared process systems for separating UF6 from
carrier gas. The carrier gas may be nitrogen, argon, or other gas.
EXPLANATORY
NOTE:
These systems may incorporate equipment such as:
Cryogenic heat exchangers or cryoseparators capable of temperatures
of -120C or less, or
Cryogenic refrigeration units capable of temperatures of -120C or
less, or
UF6 cold traps capable of temperatures of -20C or less.
28.13.
*Laser systems (AVLIS, MLIS and CRISLA) as follows:
Laser
systems specially designed or prepared for the separation of uranium
isotopes.
EXPLANATORY
NOTE:
The laser system for the AVLIS process usually consists of two lasers:
a copper vapor laser and a dye laser. The laser system for MLIS usually
consists of a CO2 or excimer laser and a multi-pass optical
cell with revolving mirrors at both ends. Laser or laser systems for
both processes require a spectrum frequency stabilizer for operation
over extended periods of time.
28.14.
Lasers, as follows:
(a)
Copper vapor lasers with 40 W or greater average output power
operating at wavelengths between 500 nm and 600 NM;
(b)
Argon ion lasers with greater than 40 W average output power
operating at wavelengths between 400 NM and 515 NM;
(c)
Neodymium-doped (other than glass) lasers as follows:
(i) Having an output wavelength between 100 NM and 1100 NM,
being pulse-excited and Q-switched with a pulse duration equal to
or greater than 1 ns, and having either of the following:
(A) A single-transverse mode output having an average output
exceeding 40 W; or
(B) A multiple-transverse mode output having an
average output power exceeding 50 W;
(ii) Operating at a wavelength between 1000 NM and
1100 NM incorporating frequency doubling giving an output wavelength
between 500 NM and 550 NM with an average power at the doubled frequency
(new wavelength) of greater than 40 W;
(d)
Tunable pulsed single-mode dye oscillators capable of an average
power output of greater than 1 W, a repetition rate greater than 1 kHz,
a pulse width less than 100 Ns, and a wavelength between 300 NM and
800 NM;
(e)
Tunable pulsed dye amplifiers and oscillators, except single-mode
oscillators, with an average power output of greater than 30 W, a repetition
rate greater than 1 kHz a pulse width less than 100 Ns, and a wavelength
between 300 NM and 800 NM;
(f)
Alexandrite lasers with a bandwidth of 0.005 NM or less, a
repetition rate of greater than 125 Hz, and an average power output
greater than 30 W operating at wavelengths between 720 NM and 800 NM;
(g)
Pulsed carbon dioxide lasers with a repetition rate greater
than 250 Hz, an average power output of greater than 500 W, and a pulse
of less than 200 Ns operating at wavelengths between 9000 NM and 11,000
NM;
NOTE:
This specification is not intended to control the higher power (typically
1 to 5 kW) industrial CO2 lasers used in applications such
as cutting and welding, as these latter lasers are either continuous
wave or are pulsed with a pulse width more than 200 Ns
(h)
Pulsed excimer lasers (XeF, XeCl, KrF) with a repetition rate
greater than 250 Hz, an average power output of greater than 500 W,
and a pulse of less than 200 Ns operating at wavelengths between 240
and 360 NM;
(i)
Para-hydrogen Raman shifters designed to operate at 16 NM output
wavelength and at a repetition rate greater than 250 Hz; and
(j)
Free electron lasers.
29.
*Systems, equipment and components for use in plasma separation enrichment
plants.
INTRODUCTORY
NOTE
In the plasma separation process, a plasma of uranium ions passes through
an electric field tuned to the 235U ion resonance frequency
so that they preferentially absorb energy and increase the diameter of
their corkscrew-like orbits. Ions with a large-diameter path are trapped
to produce a product enriched in 235U. The plasma, which is
made by ionizing uranium vapor, is contained in a vacuum chamber with
a high-strength magnetic field produced by a superconducting magnet. The
main technological systems of the process include the uranium plasma generation
system, the separator module with superconducting magnet, and metal removal
systems for the collection of 'product' and 'tails'.
29.1.
*Microwave power sources and antennae
Specially
designed or prepared microwave power sources and antennae for producing
or accelerating ions and having the following characteristics:
(a) greater than 30 GHz frequency; and
(b)
greater than 50 kW mean power output for ion production.
29.2.
*Ion excitation coils
Specially
designed or prepared radio frequency ion excitation coils for frequencies
of more than 100 kHz and capable of handling more than 40 kW mean power.
29.3.
*Uranium plasma generation systems
Specially
designed or prepared systems for the generation of uranium plasma, which
may contain high-power strip or scanning electron beam guns with a delivered
power on the target of more than 2.5 kW/cm.
29.4.
*Liquid uranium metal handling systems
Specially
designed or prepared liquid metal handling systems for molten uranium
or uranium alloys, consisting of crucibles and cooling equipment for
the crucibles.
EXPLANATORY
NOTE:
The crucibles and other parts of this system that come into contact
with molten uranium or uranium alloys are made of, or protected by,
materials of suitable corrosion and heat resistance. Suitable materials
include tantalum, yttria-coated graphite, graphite coated with other
rare earth oxides or mixtures thereof.
29.5.
*Uranium metal 'product' and 'tails' collector assemblies
Specially
designed or prepared product and 'tails' collector assemblies for uranium
metal in solid form. These collector assemblies are made of, or protected
by, materials resistant to the heat and corrosion of uranium metal vapor,
such as yttria-coated graphite or tantalum.
29.6.
*Separator module housings
Cylindrical
vessels specially designed or prepared for use in plasma separation
enrichment plants for containing the uranium plasma source, radio-frequency
drive coil and the 'product' and 'tails' collectors.
EXPLANATORY
NOTE:
These housings have a multiplicity of ports for electrical feed-throughs,
diffusion pump connections and instrumentation diagnostics and monitoring.
They have provisions for opening and closure to allow for refurbishment
of internal components and are constructed of a suitable non-magnetic
material such as stainless steel.
29.7.
*Superconducting electromagnets
Superconducting
solenoidal electromagnets with all of the following characteristics:
(a) Capable of creating magnetic fields of more than 2 teslas
(20 kilogauss);
(b)
With a L/D (length divided by inner diameter) greater than
2;
(c)
With an inner diameter of more than 300 mm; and
(d)
With a magnetic field uniform to better than 1% over the
central 50% of the inner volume.
NOTE:
This item does not cover magnets specially designed for and used as
parts of medical nuclear magnetic resonance (NMR) imaging systems.
30.
*Systems, equipment and components for use in electromagnetic enrichment
plants.
INTRODUCTORY
NOTE
In the electromagnetic process uranium metal ions produced by ionization
of a salt feed material (typically UCl4) are accelerated and
pass through a magnetic field that has the effect of causing the ions
of different isotopes to follow different paths. The major components
of an electromagnetic isotope separator include: a magnetic field for
ion-beam diversion/separation of the isotopes, an ion source with its
acceleration system, and a collection system for the separated ions. Auxiliary
systems for the process include the magnet power supply system, the ion
source high-voltage power supply system, the vacuum system, and extensive
chemical handling systems for recovery of product and cleaning/recycling
of components.
30.1.
*Electromagnetic isotope separators
Electromagnetic
isotope separators specially designed or prepared for the separation
of uranium isotopes and equipment and components therefor, including:
(a) Ion sources:
Specially
designed or prepared single or multiple uranium ion sources consisting
of a vapor source, ionizer and beam accelerator, constructed of suitable
materials such as graphite, stainless steel, or copper and capable
of providing a total ion beam current of 50 mA or greater.
(b)
Ion collectors:
Collector plates consisting of two or more slits and pockets specially
designed or prepared for collection of enriched and depleted uranium
ion beams and constructed of suitable materials such as graphite or
stainless steel.
(c)
Vacuum housings:
Specially designed or prepared vacuum housings for uranium electromagnetic
separators constructed of suitable nonmagnetic materials such as stainless
steel and designed for operation at pressures of 0.1 Pa or lower.
EXPLANATORY
NOTE:
The housings are specially designed to contain the ion sources, collector
plates and water-cooled liners and have provision for diffusion pump
connections and openings and closures for removal and reinstallation
of these components.
(d)
Magnet pole pieces:
Specially designed or prepared magnet pole pieces having a diameter
greater than 2 m used to maintain a constant magnetic field within
an electromagnetic isotope separator and to transfer the magnetic
field between adjoining separators.
30.2.
*Electromagnetic isotope separators other than those specified in 30.1
above, designed for or equipped with single or multiple ion sources
capable of providing a total ion beam current of 50 ma or greater.
30.3.
*High voltage power supplies
Specially
designed or prepared high-voltage power supplies for ion sources,capable
of continuously producing, over a time period of 8 hours, the following:
(a) Output voltage of 20,000 V or greater;
(B)
Output current of 1 A or greater; and
(C)
Voltage regulation of better than 0.1%.
30.4.
*High current power supplies
Direct
current high-power supplies capable of continuously producing, over
a period of 8 hours, the following:
(a) Output voltage of 100 V or greater, with a current output
of 500 A or greater; and
(b)
Current or voltage regulation better than 0.1%.
30.5.
Vacuum pumps
Vacuum
pumps with an input throat size of 380 mm or greater with a pumping
speed of 15,000 liters/second or greater and capable of producing an
ultimate vacuum better than 10-4 Torr (0.76 x 10-4
mbar).
TECHNICAL
NOTE:
The ultimate vacuum is determined at the input of the pump with the
input of the pump blocked off.
ANALYTICAL
INSTRUMENTS AND PROCESS CONTROL SYSTEMS USED IN URANIUM ENRICHMENT
31.
Mass spectrometers
Mass
spectrometers capable of measuring ions of 230 atomic mass units or greater
and having a resolution of better than 2 parts in 230, as follows, and
ion sources therefor;
31.1 Inductively coupled plasma mass spectrometers (ICP/MS);
31.2.
Glow discharge mass spectrometers (GDMS);
31.3.
Thermal ionization mass spectrometers (TIMS);
31.4.
*Electron bombardment mass spectrometers which have a source chamber
constructed from or lined with or plated with materials resistant to
UF6.
31.5.
Molecular beam mass spectrometers as follows:
(a) Which have a source chamber constructed from or lined
with or plated with stainless steel or molybdenum and have a cold
trap capable of cooling to 193K (-80C) or less; or
(b)
*Which have a source chamber constructed from or lined with or plated
with materials resistant to UF6
31.6.
*Mass spectrometers equipped with a microflourination ion source designed
for use with actinides or actinide flourides.
32.
Instrumentation and process control systems for use in enrichment (SC
II)
Instrumentation
for monitoring temperature, pressure, pH, fluid level or flow rate specially
designed to be corrosion resistant to UF6 by being made of,
or protected by, any of the following materials:
(a) Stainless steel;
(b)
Aluminum;
(c)
Aluminum alloys;
(d)
Nickel; and
(e)
Alloys containing 60% or more nickel.
33.
*Software especially designed for the control of uranium enrichment plant
or facilities.
OTHER
ISOTOPE SEPARATION PLANTS
34.
Plants for the production of heavy water, deuterium and deuterium compounds
and equipment therefor
INTRODUCTORY
NOTE
Heavy water can be produced by a variety of processes. However, the two
processes that have proven to be commercially viable are the water-hydrogen
sulfide exchange process (GS process) and the ammonia hydrogen exchange
process.
The
GS process is based upon the exchange of hydrogen and deuterium between
water and hydrogen sulfide within a series of towers which are operated
with the top section cold and the bottom section hot. Water flows down
the towers while the hydrogen sulfide gas circulates from the bottom to
the top of the towers. A series of perforated trays are used to promote
mixing between the gas and the water. Deuterium migrates to the water
at low temperatures and to the hydrogen sulfide at high temperatures.
Gas or water, enriched in deuterium, is removed from the first stage towers
at the junction of the hot and cold sections and the process is repeated
in subsequent stage towers. The product of the last stage, water enriched
up to 30% in deuterium, is sent to a distillation unit to produce reactor
grade heavy water i. e., 99.75% deuterium oxide.
The
ammonia-hydrogen exchange process can extract deuterium from synthesis
gas through contact with liquid ammonia in the presence of a catalyst.
The synthesis gas is fed into exchange towers and then to an ammonia converter.
Inside the towers the gas flows from the bottom to the top while the liquid
ammonia flows from the top to the bottom. The deuterium is stripped from
the hydrogen in the synthesis gas and concentrated in the ammonia. The
ammonia then flows into an ammonia cracker at the bottom of the tower
while the gas flows into an ammonia converter at the top. Further enrichment
takes place in subsequent stages and reactor grade heavy water is produced
through final distillation. The synthesis gas feed can be provided by
an ammonia plant that, in turn, can be constructed in association with
a heavy water ammonia-hydrogen exchange plant. The ammonia hydrogen exchange
process can also use ordinary water as a feed source of deuterium.
Many
of the key equipment items for heavy water production plants using the
GS or the ammonia-hydrogen exchange processes are common to several segments
of the chemical and petroleum industries. This is particularly so for
small plants using the GS process.
However,
few of the items are available "off-the-shelf". The GS and the ammonia-hydrogen
processes require the handling of large quantities of flammable, corrosive
and toxic fluids at elevated pressures. Accordingly, in establishing the
design and operating standard for plants and equipment using these processes,
careful attention to the materials selection and specifications is required
to ensure long service life with high safety and reliability factors.
The choice of scale is primarily a function of economics and need. Thus,
most of the equipment items would be prepared according to the requirements
of the customer.
Finally,
it should be noted that, in both the GS and the ammonia-hydrogen exchange
process, items of equipment which individually are not specially designed
or prepared for heavy water production can be assembled into systems which
are specially designed or prepared for producing heavy water. The catalyst
production system used in the ammonia-hydrogen exchange process and water
distillation systems used for the final concentration of heavy water to
reactor grade in either process are examples of such systems.
The
items of equipment which are specially designed or prepared for the production
of heavy water utilizing either the water-hydrogen sulfide exchange process
or the ammonia-hydrogen exchange process include the following:
34.1. Water-Hydrogen Sulfide Exchange Towers
Exchange
towers fabricated from fine carbon steel (such as ASTM A516) with diameters
of 6 m (20 ft) to 9 m (30 ft), capable of operating at pressures greater
than or equal to 2 MPa (300 psi) and with a corrosion allowance of 6
mm or greater, specially designed or prepared for heavy water production
utilizing the water-hydrogen sulfide exchange process.
34.2.
Blowers and Compressors
Single
stage, low head (i.e., 0.2 MPa or 30 psi) centrifugal blowers or compressors
for hydrogen-sulfide gas circulation (i.e., gas containing more than
70% H2S) specially designed or prepared for heavy water production
utilizing the water-hydrogen sulfide exchange process. These blowers
or compressors have a throughput capacity greater than or equal to 56
m3/second (120,000 SCFM) while operating at pressures greater
than or equal to 1.8 MPa (260 psi) suction and have seals designed for
wet H2S service.
34.3.
Ammonia-Hydrogen Exchange Towers
Ammonia-hydrogen
exchange towers greater than or equal to 35 m (114.3 ft) in height with
diameters of 1.5 m (4.9 ft) to 2.5 m (8.2 ft) capable of operating at
pressures greater than 15 MPa (2225 psi) specially designed or prepared
for heavy water production utilizing the ammonia hydrogen exchange process.
These towers also have at least one flanged, axial opening of the same
diameter as the cylindrical part through which the tower internals can
be inserted or withdrawn.
34.4.
Tower Internals and Stage Pumps
Tower
internals and stage pumps specially designed or prepared for towers
for heavy water production utilizing the ammonia-hydrogen exchange process.
Tower internals include specially designed stage contactors which promote
intimate gas/liquid contact. Stage pumps include specially designed
submersible pumps for circulation of liquid ammonia within a contacting
stage internal to the stage towers.
34.5.
Ammonia Crackers
Ammonia
crackers with operating pressures greater than or equal to 3 MPa (450
psi) specially designed or prepared for heavy water production utilizing
the ammonia-hydrogen exchange process.
34.6.
Infrared Absorption Analyzers
Infrared absorption analyzers capable of "on-line" hydrogen/deuterium
ratio analysis where deuterium concentrations are equal to or greater
than 90%.
34.7.
Catalytic Burners
Catalytic burners for the conversion of enriched deuterium gas into
heavy water specially designed or prepared for heavy water production
utilizing the ammonia-hydrogen exchange process.
34.8.
Specialized Packing
Specialized packing for use in separating heavy water from ordinary
water and made of phosphor bronze mesh or copper (both chemically treated
to improve wettability) and designed for use in vacuum distillation
towers;
34.9.
Circulating Pumps
Pumps circulating solutions of diluted or concentrated potassium amide
catalyst in liquid ammonia (KNH2/NH3) with all
of the following characteristics:
(a) Airtight (i.e. hermetically sealed);
(b)
For concentrated potassium amide solutions (1% or greater),
operating pressure of 1.5-60 MPa; for dilute potassium amide solutions
(less than 1%) operating pressure of 20-60 MPa; and
(c)
A capacity greater than 8.5 m^3/h;
34.10.
Ammonia synthesis converters
Ammonia synthesis units in which the synthesis gas (nitrogen and hydrogen)
is withdrawn from an ammonia/hydrogen high-pressure exchange column
and the synthesized ammonia is returned to said column;
34.11.
Platinized catalysts
Platinized catalysts specially designed or prepared for promoting the
hydrogen isotope exchange reaction between hydrogen and water for the
recovery of tritium from heavy water or for the production of heavy
water.
34.12.
Hydrogen-cryogenic distillation columns having all of the following
applications:
(a) designed to operate with internal temperatures of -238oC
(35 K) or less;
(b)
designed to operate at internal pressure of 0.5 to 5 MPa
(5 to 50 atmospheres);
(c)
constructed of fine-grain stainless steels of the 300 series
with low sulfur content or equivalent cryogenic and H2-compatible
materials; and
(d)
with internal diameters of 1 m or greater and effective lengths
of 5 m or greater.
35.
*Plants and specially designed equipment for the separation of lithium-6
36.
*Facilities or plants for the production, recovery, extraction, concentration
or handling of tritium, and equipment and materials therefor, as follows:
36.1 Tritium storage, separation, purification, and pumping
systems using metal hydrides as the storage, pumping or purification
medium;
36.2.
Hydrogen or helium refrigeration units capable of cooling to
23 K (-250C ) or less, with heat removal capacity greater than 150 watts.
NOTE:
See
also item 19.
PLANTS
AND EQUIPMENT FOR THE CONVERSIONOF URANIUM
INTRODUCTORY
NOTE
Uranium
conversion plants and systems may perform one or more transformations
from one uranium chemical species to another, including:
conversion of uranium ore concentrates to UO3;
conversion
of UO3 to UO2;
conversion
of uranium oxides to UF4 or UF6;
conversion
of UF6 to UF4;
conversion
of UF4, to UF6;
conversion
of UF4, to uranium metal;,
conversion
of uranium fluorides to UO2; and
conversion
of uranium oxides to UCl4.
Many
of the key equipment items for uranium conversion plants are common to
several segments of the chemical process industry. For example the types
of equipment employed in these processes may include furnaces, rotary
kilns, fluidized bed reactors, flame tower reactors, liquid centrifuges,
distillation columns and liquid-liquid extraction columns. However, few
of the items are available "off-the-shelf"; most would be prepared according
to the requirements and specifications of the customer. In some instances,
special design and construction considerations are required to address
the corrosive properties of some of the chemicals handled (HF, F2,
ClF3, and uranium fluorides). Finally, it should be noted that,
in all of the uranium conversion processes, items of equipment which individually
are not specially designed or prepared for uranium conversion can be assembled
into systems which are specially designed or prepared for use in uranium
conversion.
37.
Specially designed or prepared systems for the conversion of uranium ore
concentrates to U03
EXPLANATORY
NOTE:
Conversion of uranium ore concentrates to UO3 can be performed
by first dissolving the ore in nitric acid and extracting purified uranyl
nitrate using a solvent such as tributyl phosphate. Next, the uranyl nitrate
is converted to UO3 either by concentration and denitration,
or by neutralization with gaseous ammonia to produce ammonium diuranate
with subsequent filtering, drying, and calcining
38.
*Specially designed or prepared systems for the conversion of UO3 to UF6
EXPLANATORY NOTE:
Conversion of UO3 to UF6 can be performed directly
by fluorination. The process requires a source of fluorine gas or chlorine
trifluoride.
39.
Specially designed or prepared systems for the conversion of UO3
to UO2
EXPLANATORY
NOTE:
Conversion of UO3 to UO2 can be performed through
reduction of UO3 with cracked ammonia gas or hydrogen.
40.
Specially designed or prepared systems for the conversion of UO2
to UF4
EXPLANATORY
NOTE:
Conversion of UO2 to UF4 , can be performed by reacting
UO2 with hydrogen fluoride gas (HF) at 300-500 C.
41.
*Specially designed or prepared systems for the conversion of UF4 to UF6
EXPLANATORY NOTE:
Conversion of UF4 to UF6 is performed by exothermic
reaction with fluorine in a tower reactor. UF6 is condensed
from the hot effluent gases by passing the effluent stream through a cold
trap cooled to -10C (263 K). The process requires a source of fluorine
gas.
42.
Specially designed or prepared systems for the conversion of UF4
to U metal
EXPLANATORY
NOTE:
Conversion of UF4 to U metal is performed by reduction with
magnesium (large batches) or calcium (small batches). The reaction is
carried out at temperatures above the melting point of uranium (1130C).
43.
*Specially designed or prepared systems for the conversion of UF6 to UO2
EXPLANATORY NOTE:
Conversion of UF6 to UO2 can be performed by one
of three processes. In the first, UF6 is reduced and hydrolyzed
to UO2 using hydrogen and steam. In the second, UF6
is hydrolyzed by solution in water, ammonia is added to precipitate ammonium
diuranate, and the diuranate is reduced to UO2 with hydrogen
at 820C. In the third process, gaseous UF6, CO2
and NH3 are combined in water, precipitating ammonium uranyl
carbonate. The ammonium uranyl carbonate is combined with steam and hydrogen
at 500-600C to yield UO2. UF6 to UO2
conversion is often performed as the first stage of a fuel fabrication
plant.
44.
*Specially designed or prepared systems for the conversion of UF6 to UF4
EXPLANATORY NOTE:
Conversion of UF6 to UF4 is performed by reduction
with hydrogen.
43.
*Specially designed or prepared systems for the conversion of UO2 to UCl4.
EXPLANATORY NOTE:
Conversion of UO2 to UCl4 can be performed by reacting
UO2 with CCl4 at high temperature.
46.
Electrolytic cells for fluorine production with a production capacity
greater than 250 grams of fluorine per hour and specially designed parts
and accessories therefor (SC II)
NUCLEAR
REACTORS AND EQUIPMENT THEREFOR
47.
Complete nuclear reactors
Nuclear
reactors capable of operation so as to maintain a controlled self sustaining
fission chain reaction.
EXPLANATORY
NOTE:
A "nuclear reactor" basically includes the items within, or attached directly
to, the reactor vessel, the equipment which controls the level of power
in the core, and the components which normally contain, or come in direct
contact with, or control the primary coolant of the reactor core.
47.1. Reactor Vessels
Metal
vessels, as complete units or as major shop-fabricated parts therefor,
which are specially designed or prepared to contain the core of a nuclear
reactor as defined in paragraph 47 above and are capable of withstanding
the operating pressure of the primary coolant.
EXPLANATORY
NOTE:
A top plate for a reactor vessel is covered by item 47.1 as a major
shop-fabricated part.
Reactor
internals (e.g. support columns and plates for the core and other vessel
internals, control rod guide tubes, thermal shields, baffles, core grid
plates, diffuser plates, etc.) are normally supplied by the reactor
supplier. In some cases, certain internal support components are included
in the fabrication of the reactor vessel. These items are sufficiently
critical to the safety and reliability of the operation of the reactor
(and, therefore, to the guarantees and the liability of the reactor
supplier), so that their supply, outside the basic supply arrangement
for the reactor itself, would not be common practice. Therefore, although
the separate supply of these unique, specially designed and prepared,
critical, large and expensive items would not necessarily be considered
as falling outside the area of concern, such a mode of supply is considered
unlikely.
47.2.
Reactor fuel charging and discharging machines
Manipulative equipment specially designed or prepared for inserting
or removing fuel in a nuclear reactor capable of on-load operation or
employing technically sophisticated positioning or alignment features
to allow complex off-load fueling operations such as those in which
direct viewing or access to the fuel is not normally available.
47.3.
Reactor control rods
Rods specially designed or prepared for the control of the reaction
rate in a nuclear reactor.
EXPLANATORY
NOTE:
This item includes, in addition to the neutron absorbing part, the support
or suspension structures therefor, if supplied separately.
47.4.
Reactivity control mechanisms, devices and systems
EXPLANATORY
NOTE:
Reactivity control mechanisms, devices, and systems may be manual, electro-mechanical,
hydraulic, pneumatical and chemical injection/removal type.
47.5.
Reactor pressure tubes
Tubes which are specially designed or prepared to contain fuel elements
and the primary coolant in a reactor at an operating pressure in excess
of 5.1 MPa (740 psi).
47.6.
Primary coolant pumps
Pumps specially designed or prepared for circulating the primary coolant
for nuclear reactors.
EXPLANATORY
NOTE:
Specially designed or prepared pumps may include elaborate sealed or
multi-sealed system to prevent leakage of primary coolant, canned-driven
pumps and pumps with inertial mass systems. This definition encompasses
pumps certified to NC-1 (or equivalent) standards.
47.7.
Reactor process monitoring measurement and process control
systems
Reactor process monitoring , measurement and control systems, sub-systems
and components. All analog and digital process control computers and
hydraulic and pneumatic process monitoring and control instruments and
equipment.
NUCLEAR
FUELFABRICATION PLANTS
48.
Plants for the fabrication of fuel elements
A
"plant for the fabrication of fuel elements" includes the equipment:
48.1 Which normally comes in direct contract with, or directly
processes, or controls, the production flow of nuclear material; or
48.2.
Which seals the nuclear material within the cladding; or
48.3.
Which checks the integrity of the cladding or the seal; or
48.4.
Which provides for the finishing surface treatment of the sealed
fuel.
REPROCESSING
TECHNOLOGY AND EQUIPMENT THEREFOR
49.
*Plants and equipment for the reprocessing of irradiated fuel elements
INTRODUCTORY
NOTE
Reprocessing irradiated fuel separates plutonium and uranium from intensely
radioactive fission products and other transuranic elements. Different
technical processes can accomplish this separation. However, over the
years Purex has become the most commonly used and accepted process. Purex
involves the dissolution of irradiated nuclear fuel in nitric acid, followed
by separation of the uranium, plutonium, and fission products by solvent
extraction using a mixture of tributyl phosphate in an organic diluent.
Purex facilities have process functions similar to each other, including:
irradiated fuel element chopping, fuel dissolution, solvent extraction,
and process liquor storage. There may also be equipment for thermal denitration
of uranium nitrate, conversion of plutonium nitrate to oxide or metal,
and treatment of fission product waste liquor to a form suitable for long
term storage or disposal. However, the specific type and configuration
of the equipment performing these functions may differ between Purex facilities
for several reasons, including the type and quantity of irradiated nuclear
fuel to be reprocessed and the intended disposition of the recovered materials
and the safety and maintenance philosophy incorporated into the design
of the facility.
A
"plant for the reprocessing of irradiated fuel elements" includes the
equipment and components which normally come in direct contact with, and
directly control the irradiated fuel and the major nuclear material and
fission product processing streams.
These
processes, including the complete systems for plutonium conversion and
plutonium metal production, may be identified by the measures taken to
avoid criticality (e.g. by geometry), radiation exposure (e.g. by shielding),
and toxicity hazards (e.g. by containment).
49.1.
*Irradiated fuel element chopping machines
INTRODUCTORY
NOTE
This equipment breaches the cladding of the fuel to expose the irradiated
nuclear material to dissolution. Specially designed metal cutting shears
are the most commonly employed, although advanced equipment, such as
lasers, may be used.
Remotely
operated equipment specially designed or prepared for use in a reprocessing
plant as identified above and intended to cut, chop, or shear irradiated
nuclear fuel assemblies, bundles, or rods.
49.2.
*Dissolvers
INTRODUCTORY
NOTE
Dissolvers normally receive the chopped-up spent fuel. In these critically
safe vessels, the irradiated nuclear material is dissolved in nitric
acid and the remaining hulls are removed from the process stream.
Critically
safe tanks (e.g. small diameter, annular, or slab tanks) specially designed
or prepared for use in a reprocessing plant as identified above, intended
for dissolution of irradiated nuclear fuel, and which are capable of
withstanding hot, highly corrosive liquid, and which can be remotely
loaded and maintained.
49.3.
*Solvent extractors and solvent extraction equipment
INTRODUCTORY
NOTE
Solvent extractors both receive the solution of irradiated fuel from
the dissolvers and the organic solution which separates the uranium,
plutonium, and fission products. Solvent extraction equipment is normally
designed to meet strict operating parameters, such as long operating
lifetimes with no maintenance requirements or adaptability to easy replacement,
simplicity of operation and control, and flexibility for variations
in process conditions.
Specially
designed or prepared solvent extractors such as packed or pulse columns,
mixer settlers or centrifugal contactors for use in a plant for the
reprocessing of irradiated fuel. Solvent extractors must be resistant
to the corrosive effect of nitric acid. Solvent extractors are normally
fabricated to extremely high standards (including special welding and
inspection and quality assurance and quality control techniques) out
of low carbon stainless steels, titanium, zirconium, or other high quality
materials.
49.4.
*Chemical holding or storage vessels
INTRODUCTORY
NOTE
Three main process liquor streams result from the solvent extraction
step. Holding or storage vessels are used in the further processing
of all three streams, as follows:
The
pure uranium nitrate solution is concentrated by evaporation and passed
to a denitration process where it is converted to uranium oxide. This
oxide is re-used in the nuclear fuel cycle.
The
intensely radioactive fission products solution is normally concentrated
by evaporation and stored as a liquor concentrate. This concentrate
may be subsequently evaporated and converted to form suitable for storage
or disposal.
The
pure plutonium nitrate solution is concentrated and stored pending its
transfer to further process steps. In particular, holding or storage
vessels for plutonium solutions are designed to avoid criticality problems
resulting from changes in concentration and form of this stream.
Specially
designed or prepared holding or storage vessels for use in a plant for
the reprocessing of irradiated fuel. The holding or storage vessels
must be resistant to the corrosive effect of nitric acid. They are normally
fabricated of materials such as low carbon stainless steels, titanium,
or zirconium, or other high quality materials. Holding and storage vessels
may be designed for the remote operation and maintenance and may have
the following features for control of nuclear criticality:
(a) *Walls or internal structures with a boron equivalent
of a least 2%; or
(b) *A maximum diameter of 175 mm (7 in) for cylindrical vessels;
or
(c) *A maximum width of 75 mm (3 in) for either a slab or
annular vessel.
49.5.
*Plutonium nitrate to oxide conversion system
INTRODUCTORY
NOTE
In most reprocessing facilities, this final process involves the conversion
of the plutonium nitrate solution to plutonium dioxide. The main functions
involved in this process are:
process
feed storage and adjustment, precipitation, and solid/liquid separation,
calcination, product handling, ventilation, waste management, and process
control.
Complete
systems specially designed or prepared for the conversion of plutonium
nitrate to plutonium oxide, in particular adapted so as to avoid criticality
and radiation effects and to minimize toxicity hazards.
49.6.
*Plutonium oxide to metal production system
INTRODUCTORY
NOTE
This process, which could be related to a reprocessing facility, involves
the fluorination of plutonium dioxide, normally with highly corrosive
hydrogen fluoride, to produce plutonium fluoride which is subsequently
reduced using high purity calcium metal to produce metallic plutonium
and calcium fluoride slag. The main functions involved in this process
are: fluorination (e.g. involving equipment fabricated or lined with
a precious metal), metal reduction (e.g. employing ceramic crucibles),
slag recovery, product handling, ventilation, waste management and process
control.
Complete
systems specially designed or prepared for the production of plutonium
metal, in particular adapted so as to avoid criticality and radiation
effects and to minimize toxicity hazards.
49.7.
*Hot cells and related equipment specially designed or prepared
for the handling and processing of irradiated nuclear material
EXPLANATORY
NOTE:
Small scale chemical separation of plutonium or uranium or both from
irradiated nuclear material requires radiation protection from fission
products' gamma activity and from plutonium toxicity. This separation
is normally conducted in specially designed or prepared lead- or concrete-
shielded cells provided with viewing ports made of high density glass
and remote manipulators. Protection from plutonium toxicity is obtained
with an air-tight internal lining of the hot the cell normally made
of low-carbon steel. Hot cells are provided with air extraction system
capable of maintaining a slightly negative pressure and equipped with
high efficiency particulate air filters which prevent the release of
aerosols from the hot cell into the environment.
49.8.
Hot cells related equipment specially designed or prepared
for the handling or processing of radioisotopes or radiation sources
in medical and industrial applications as follows:
(a) Remote manipulators that provide mechanical translation
of human operator actions by electrical, hydraulic, or mechanical
means to an operating arm and terminal fixture, that can be used to
provide remote actions in radiochemical separation operations and
hot cells as follows:
(i) Having a capability of penetrating 0.6 m or more of
cell wall ('through the wall' operation); or
(ii) Having a capability of bridging over the
top of a cell wall with a thickness of 0.6 m or more ('over the
wall' operation);
NOTE:
Remote
manipulation may be of a 'master/slave' type or operated by a joystick
or keypad.
(b)
High-density (lead glass or other) radiation shielding windows
greater than 0. 3 m on a side and with a density greater than 3 g/cm3
and a thickness of 100 mm or greater and specially designed frames
therefor;
(c)
Radiation hardened TV cameras specially designed or rated
as radiation hardened to withstand greater than 5 x 104
grays (SI) (5 x 106 rad) without operational degradation
and specially designed lenses used therein;
(d)
Casks designed for transportation or storage of nuclear reactor
fuel or irradiated fuel elements.
INDUSTRIAL EQUIPMENT AND MACHINE TOOLS
50.
*Rotor fabrication and assembly equipment and bellows forming mandrels
and dies, as follows:
50.1 Rotor assembly equipment for assembly of rotor tube sections,
baffles, and end caps including associated precision mandrels, clamps
and shrink fit machines;
50.2.
Rotor straightening equipment for alignment of rotor tube
sections to a common axis;
NOTE:
Normally such equipment will consist of precision measuring probes linked
to a computer that subsequently controls the action of, for example,
pneumatic rams used for aligning the rotor tube sections.
50.3.
Bellows forming mandrels and dies for producing single-convolution
bellows i.e., bellows made of high strength aluminum alloys, maraging
steel or high-strength filamentary materials. The bellows have all of
the following dimensions:
(a) 75
mm to 400 mm (3 in to 16 in ) inside diameter;
(b)
12.7 mm (0.5 in) or more in length; and
(c)
Single convolution depth more than 2 mm (0.08 in)
NOTE:
Items under (c) are two-piece cylindrical with a single indented circumferential
convolution bisected by the two halves.
51.
*Centrifugal balancing machines
Centrifugal
multi-plane balancing machines, fixed or portable, horizontal or vertical,
as follows; and specially designed software therefor:
51.1 Centrifugal balancing machines designed for balancing flexible
rotors having a length of 400 mm or more and having all the following
characteristics:
(a) A swing or journal diameter of 75 mm or more;
(b)
Mass capability of from 0.9 to 23 kg; and
(c)
Capable of balancing speed of revolution more that 5000 rpm;
51.2.
Centrifugal balancing machines designed for balancing hollow
cylindrical rotor components and having all the following characteristics:
(a) A journal diameter of 75 mm or more;
(b)
Mass capability of from 0.9 to 23 kg;
(c)
Capable of balancing to a residual imbalance of 0.010 kg
mm/kg per plane or better; and
(d)
Belt drive type.
52.
*Filament winding machines (SC IV)
Filament winding machines in which the motions for positioning, wrapping
and winding fibers are coordinated and programmed in two or more axes,
specially designed to fabricate composite structures or laminates from
fibrous or filamentary materials and capable of winding cylindrical rotors
of diameter between 75 mm and 400 mm and lengths of 400 mm or greater;
coordinating and programming controls therefor; precision mandrels; and
specially designed software therefor.
53.
Spin-forming and flow-forming machines (SC IV)
Spin-forming
and flow-forming machines and precision rotor-forming mandrels designed
to form cylindrical rotors of inside diameter between 75 mm and 400 mm;
and specially designed software therefor, which:
53.1. According to the manufacturer's technical specification,
can be equipped with numerical control units or a computer control;
and
53.2.
Have two or more axes that can be coordinated simultaneously
for contouring control.
NOTE:
The only spin-forming machines included into this entry are those combining
the function of spin-forming and flow-forming.
54.
Dimensional inspection machines
Dimensional
inspection machines, devices or systems, as follows, and specially designed
software therefor.
54.1. Computer controlled or numerically controlled dimensional
inspection machines having both of the following characteristics:
(a) Two or more axes; and
(b)
A one-dimensional length measurement uncertainty equal to
or less (better) than (6 � L/1000) Mm (L is the measured length
in millimeters) (Ref.VDI/VDE 2617 parts 1 and 2).
54.2.
Linear and angular displacement measuring devices, as follows:
(a) Linear measuring instruments having any of the following
characteristics:
(i) Non-contact type measuring systems with a "resolution"
equal to or less (better) than 0.2 Mm within a measuring
range up to 0.2 mm; or
(ii)
Linear voltage differential transformer (LVDT) systems
having both of the following characteristics:
(A) Linearity
equal to or less (better) than 0.1% within a measuring range up
to 5 mm; and
(B)
Drift equal to or less (better) than 0.1% per day at
a standard ambient test room temperature � 1K; or
(iii)
Measuring systems that have both of the following characteristics:
(A) Contain a laser; and
(B)
Maintain for at least 12 hours, over a temperature range
of � 1K around a standard temperature and a standard pressure:
(I) A resolution over their full scale of 0.1 Mm
or better; and
(II)
A "measurement uncertainty" equal to or less (better)
than (0.2 �L/2000) Mm (L is the measured length in millimeters);
except measuring interferometer systems, without closed
or open loop feedback, containing a laser to measure slide movement
errors of machine tools, dimensional inspection machines, or
similar equipment;
(b)
Angular measuring instruments having an angular position
deviation equal to or less (better) than 0.00025;
NOTE:
This item does not include optical instruments, such as autocollimators,
using collimated light to detect angular displacement of a mirror.
(c)
Systems for simultaneous linear-angular inspection of
hemishells, having both of the following characteristics:
(i) "Measurement uncertainty" along any linear
axis equal to or less (better) than 3.5 Mm per 5 mm; and
(ii) Angular position deviation equal to or less
than 0.02.
NOTE:
Specially designed software for the systems described in paragraph (c)
of this item includes software for simultaneous measurement of wall
thickness and contour.
TECHNICAL
NOTE 1:
Machine tools that can be used as measuring machines are included if
they meet or exceed the criteria specified for the machine tool function
or the measuring machine function.
TECHNICAL
NOTE 2:
A machine described in paragraph 54 is included if it exceeds the control
threshold anywhere within its operating range.
TECHNICAL
NOTE 3:
The probe used in determining the "measurement uncertainty" of a dimensional
inspection system shall be as described in VDI/VDE 2617 parts 2, 3 and
4.
TECHNICAL
NOTE 4:
All parameters of measurement
values in this item represent plus/minus, i.e. not total band.
"Measurement uncertainty"
The
characteristic parameter which specifies in what range around the
output value the correct value of the measurable variable lies with
a confidence level of 95%. It includes the uncorrected systematic
deviations, the uncorrected backlash, and the random deviations
(Reference: VDI/VDE 2617).
"Resolution"
The least increment of a measuring device; on digital instruments,
the least significant bit (Reference:ANSI B-89.1.12).
"Linearity"
(Usually measured in terms of non-linearity) is the maximum deviation
of the actual characteristic (average of upscale and downscale readings),
positive or negative, from a straight line so positioned as to equalize
and minimize the maximum deviations.
"Angular
position deviation"
The maximum difference between angular position and the actual,
very accurately measured angular position after the workpiece mount
of the table has been turned out of its initial position. (Reference:
VD1/VDE 2617. Draft: "Rotary table on coordinate measuring machines").
55.
Electron beam welding machines
Electron
beam welding machines with a chamber of 0.5 m3 or more
.56.
Plasma spray systems
Plasma
spray systems, atmospheric or vacuum.
57.
Oxidation furnaces
Vacuum
oxidation furnaces with all of the following characteristics:
(a) Having a steam supply capable of introducing slightly
superheated steam into the bottom of the furnace at a controlled rate;
(b)
Capable of containing a retort of working diameter of 600
mm or more and a workable height of 1200 mm or more; and
(c)
Having a radiant heater to uniformly heat the retort to a
temperature of 673 K (400oC) or more.
TECHNICAL
NOTE:
Oxidation furnaces are used to deposit a controlled oxide layer on the
surface of the centrifuge components made from maraging steel.
58.
High temperature furnaces
58.1.
*Vacuum or controlled environment (inert gas) induction furnaces
capable of operation above 1123 K (850oC) and having induction coils
600 mm or less in diameter, and power supplies specially designed for
induction furnaces with a power supply of 5 kW or more
TECHNICAL
NOTE:
This entry does not include furnaces designed for the processing of
semiconductor wafers.
58.2.
*Vacuum or controlled environment metallurgical melting and casting
furnaces as follows; and specifically configured computer control
and monitoring systems and specially designed software therefor:
(a) Arc
remelt and casting furnaces with consumable electrode capacities
between 1000 cm3 and 20,000 cm3
and capable of operating with melting temperatures above 1973
K (1700C); and
(b)
Electron beam melting and plasma atomization and melting
furnaces with a power of 50 kW or greater and capable of operating
with melting temperatures above 1473 K (1200C).
59.
Isostatic presses (cold and hot) (SC IV)
Isostatic
presses capable of achieving a maximum working pressure of 69 MPa or greater
and having a chamber cavity with an inside diameter in excess of 152 mm;
and specially designed dies and molds, components, accessories and controls;
and specially designed software therefor.
TECHNICAL
NOTE 1:
Isostatic presses are presses capable of pressurizing a closed cavity
through various media (gas, liquid, solid particles) to create equal pressure
in all directions within the cavity upon a workpiece of material.
TECHNICAL
NOTE 2:
The inside chamber dimension is that of the chamber in which both the
working temperature and the working pressure are achieved and does not
include fixtures. That dimension is smaller of either the inside diameter
of the pressure chamber or the inside diameter of the insulated furnace
chamber, depending on which of the two chambers is located inside the
other.
60.
Machine tools (SC IV)
60.1. Numerical control units, specially designed motion control
boards for numerical control applications on machine tools, numerically
controlled machine tools, specially designed software, and related
technology. Detailed specifications of the equipment are set out in
the Appendix to Annex 3.
60.2.
*Turning, milling and grinding machines having any of the following
characteristics:
(a) Vacuum
chucks suitable for holding hemispherical parts;
(b)
Machines installed within glove boxes or equivalent containment
facilities; and
(c)
Explosion-proofing features.
61.
Vibration test equipment (SC IV)
Vibration
test systems, equipment, components and software therefor, as follows:
61.1. Vibration test systems, employing feedback or closed
loop control techniques and incorporating a digital controller, capable
of vibrating a system at 10 g RMS or more anywhere in the range 20
Hz to 2000 Hz and imparting forces of 50 kN (11,250 lbs), measured
'bare table', or greater;
61.2.
Digital controllers, combined with "specially designed software"
for vibration testing, with a real-time bandwidth greater than 5 kHz
and being designed for use with the systems controlled in 61.1.above;
61.3.
Vibration thrusters (shaker units), with or without associated
amplifiers, capable of imparting a force of 50 kN (11,250 lbs), measured
"bare table", or greater, which are usable for the systems controlled
in 61.1.above;
61.4.
Test piece support structures and electronic units designed
to combine multiple shaker units into a complete shaker system capable
of providing an effective combined force of 50 kN, measured 'bare
table', or greater, which are usable for the systems controlled in
61.1 above.
EXPLANATORY
NOTE:
The term 'bare table' refers to a flat table or surface with
no fixtures or fittings.
61.5.
"Specially designed software" for use with the systems controlled
in 61.1.above or for the electronic units controlled in 61.4.above.
62.
"Robots" and "end-effectors" having any of the following characteristics;
and specially designed controllers and software therefor:
62.1. Specially designed to comply with national safety standards
applicable to explosive environments (for example, meeting electrical
code ratings for explosive environments);
62.2.
Specially designed or rated as radiation hardened more than
necessary to withstand normal industrial (i.e. non-nuclear industry)
ionizing radiation.
NOTE:
See Appendix to Annex 3 for definitions.
IMPLOSION
SYSTEMS DEVELOPMENT EQUIPMENT
63.
*Specialized equipment for hydrodynamic experiments, as follows:
63.1. Velocity interferometers for measuring velocities in
excess of 1 km per second during time intervals less than 10s (VISARs,
Doppler laser interferometers, DLIs, etc.);
63.2.
Manganin gauges for pressures greater than 100 kilobars;
63.3.
Quartz pressure transducers for pressures greater than 100
kilobars;
63.4.
Pindomes; or
63.5.
Schliering systems.
64.
Flash X-ray equipment
Flash
X-ray generators or pulsed electron accelerators with peak energy of 500
keV or greater as follows, except accelerators that are component parts
of devices designed for purposes other than electron beam or x-ray radiation
(electron microscopy, for example) and those designed for medical purposes:
64.1.
Having an accelerator peak electron energy of 500 keV or greater,
but less than 25 MeV and with a figure of merit (K) of 0.25 or greater,
where K is defined as:
K=1.7
x 10^3 V ^2.65 Q
where
V is the peak electron energy in million electron volts and Q
is the total accelerated charge in coulombs if the accelerator beam
pulse duration is less than or equal to 1 �s; if the accelerator beam
pulse duration is greater than 1 �s, Q is
the maximum accelerated charge in 1 �s [Q
equals the integral of i with respect to t,
over the lesser of 1 �s or the time duration of the beam pulse (Q
= (integral)idt), where i is the beam current in amperes
and t is the time in seconds] or,
64.2.
Having an accelerator peak electron energy of 25 MeV or
greater and a peak power greater than 50 MW. [Peak power = (peak potential
in volts) x (peak beam current in amperes).]
TECHNICAL
NOTE:
Time duration of the beam pulse In machines, based on microwave accelerating
cavities, the time duration of the beam pulse is the lesser of 1 �s
or the duration of the bunched beam packet resulting from one microwave
modulator pulse.
Peak
beam current In machines based on microwave accelerating cavities,
the peak beam current is the average current in the time duration
of a bunched beam packet.
65.
*Gun systems
Multistage
gas guns or other high-velocity gun systems (coil, electromagnetic, electrothermal,
or other advanced systems) capable of accelerating projectiles to 2 km
per second or greater.
66.
*Mechanical rotating mirror cameras
Mechanical framing cameras with recording rates greater than 225,000 frames
per second; streak cameras with writing speeds greater than 0.5 mm per
microsecond; and parts and accessories thereof, including synchronizing
electronics specially designed for this purpose and specially designed
rotor assemblies (consisting of turbines, mirrors, and bearings).
67.
*Electronic streak and framing cameras and tubes as follows:
67.1. Electronic streak cameras capable of 50 Ns or less time
resolution and streak tubes therefor;
67.2.
Electronic (or electronically shuttered) framing cameras capable
of 50 Ns less frame exposure time including single frame cameras;
67.3.
Framing tubes and solid-state imaging devices for use with
cameras controlled in 67.2 above, as follows:
(a) proximity focused image intensifier tubes having the
photocathode deposited on a transparent conductive coating to
decrease photocathode sheet resistance;
(b)
gate silicon intensifier target (SIT) vidicon tubes,
where a fast system allows gating the photoelectons from the photocathode
before they impinge on the SIT plate;
(c)
Kerr or pockel cell electro-optical shuttering; or
(d)
Other framing tubes and solid-state imaging devices having
a fast-image gating time of less than 50 Ns specially designed for
cameras controlled in 67.2 above.
68.
*Computer codes for nuclear explosives
Hydrodynamics codes, neutronic codes, and/or equation-of-state and related
nuclear data files usable for calculating implosion or gun type weapons.
NOTE:
These items include software, equations or data in any form usable for
calculating implosion or gun type weapons.
69.
Detonators and multi-point initiator systems
Detonators
and multipoint initiation systems:
69.1. Electrically driven explosive detonators as follows:
(a) Exploding bridge (EB);
(b)
Exploding bridge wire (EBW);
(c)
Slapper; and
(d)
Exploding foil initiators (EFI).
69.2.
Arrangements using single or multiple detonators designed
to nearly simultaneously initiate an explosive surface (over greater
than 5000 mm^2) from a single firing signal (with an initiation
timing spread over the surface of less than 2.5 �s).
TECHNICAL
NOTE:
The detonators of concern all utilize a small electrical conductor (bridge,
bridge wire, or foil) that explosively vaporizes when a fast, high-current
electrical pulse is passed through it. In non-slapper types, the exploding
conductor starts a chemical detonation in a contacting high-explosive
material such as PETN (pentaerythritoltetranitrate). In slapper detonators,
the explosive vaporization of the electrical conductor drives a "flyer"
or "slapper" across a gap, and the impact of the slapper on the explosive
starts a chemical detonation . The slapper in some designs is driven by
magnetic force. The term "exploding foil" detonator may refer to either
an EB or a slapper-type detonator. Also, the word "initiator" is sometimes
used in place of the word "detonator".
Detonators
using only primary explosives, such as lead azide, are not subject to
control.
70.
*Explosive lenses
Explosive lenses designed to uniformly initiate the detonation
of the surface of a high explosive charge.
71.
*Firing sets and equivalent high-current pulse generators (for controlled
detonators)
71.1. Explosive detonator firing sets designed to drive multiple
controlled detonators covered under item 69 above;
71.2.
Modular electrical pulse generators (pulsers) designed for
portable, mobile or ruggedized use (including xenon flashlamp drivers),
with the following characteristics:
(a) Capable of delivering their energy in less than 15
microseconds;
(b) Having an output greater than 100 A;
(c) Having a rise time of less that 10 microseconds
into loads of less than 40 ohms. (Rise time is defined as the
time interval from 10% to 90% current amplitude when driving a
resistive load);
(d) Enclosed in a dust-tight enclosure;
(e) No dimension greater than 25.4 cm (10 in
);
(f) Weight less than 25 kg (55 lb); and
(g) Specified for use over an extended temperature
range (-50oC to 100oC) or specified as suitable
for aerospace use.
72.
Switching devices, as follows:
72.1. Cold-cathode tubes (including gas krytron tubes and
vacuum sprytron tubes), whether gas filled or not, operating similarly
to a spark gap, containing three or more electrodes, and having all
of the following characteristics:
(a) Anode peak voltage rating of 2500 V or more;
(b)
Anode peak current rating of 100 A or more; and
(c)
Anode delay time of 10 microseconds or less;
72.2.
Triggered spark-gaps having an anode delay time of 15 microseconds
or less and rated for a peak current of 500 A or more;
72.3.
Modules or assemblies with a fast switching function having
all of the following characteristics:
(a) Anode peak voltage rating greater than 2000V;
(b)
Anode peak current rating of 500 A or more; and
(c)
Turn-on time of 1 s or less.
73.
Capacitors with either of the following sets of characteristics:
73.1. Voltage rating greater than 1.4 kV, energy storage greater
than 10J, capacitance greater than 0.5 �F,
and series inductance less than 50 nH; or
73.2.
Voltage rating greater than 750 V, capacitance greater than
0.25 �F,
and series inductance less than 10 nH.
74.
High explosives (SC IV)
High
explosive, in any form, including shells and hollow spheres, as follows:
74.1. Cyclotetramethylenetetranitroamine (HMX);
74.2.
Cyclotrimethylenetrinitroamine (RDX);
74.3.
Triaminotrinitrobenzene (TATB);
74.4.
Pentaerythritoltetranitrate (PETN); except when contained
in pharmaceuticals;
74.5.
Hexanitrostilbene (HNS), except when contained in pharmaceuticals;
and
74.6.
Any explosive with a crystal density greater than 1.8 g/cm3
and having a detonation velocity greater than 8000 m/s.
OTHER
EQUIPMENT
75.
Crucibles, as follows:
75.1.
*Crucibles made of any of the following materials
(a) Calcium
fluoride (CaF2);
(b)
Calcium zirconate (metazirconate) (Ca2ZrO3);
(c)
Cerium sulfide (Ce2S3);
(d)
Erbium oxide (erbia) (Er2O3);
(e)
Hafnium oxide (hafnia) (HfO2);
(f)
Magnesium oxide (MgO);
(g)
Nitrided niobium-titanium-tungsten alloy (approximately
50% Nb, 30% Ti, 20%W);
(h)
Yttrium oxide (yttria) (Y2O3);
or
(i)
Zirconium oxide (zirconia) (ZrO2);
75.2.
*Crucibles made of or lined with tantalum, having a purity of 99.9%
or greater;
75.3.
*Crucibles
made of or lined with tantalum (having a purity of 98% or greater)
coated with tantalum carbide, nitride or boride (or any combination
of these)
76.
Alpha sources
Alpha-emitting
radionuclides, as follows; and equipment containing such alpha-emitting
radionuclides
(a) Radionuclides, including compounds and mixtures, which:
(i) Have an half-life of 10 days or greater, but less
than 200 years; and
(ii)
Have a total alpha activity of 37 Gbq per kilogram (1
curie per kilogram) or greater;
except:
devices containing less than 100 millicuries (3.7 Gbq) of alpha
activity per device;
(b)
Radium-226 in any form;
except:
when contained in medical applicators
77.
Neutron generator systems
77.1.
*Neutron generator systems, including tubes, designed for operation
without an external vacuum system and utilizing electrostatic acceleration
to induce a tritium-deuterium reaction, capable of producing more
that 3x10^3 neutron/ms.
77.2.
Neutron generator systems to utilize dense plasma focus for
deuterium-deuterium or tritium-deuterium reaction.
78.
Electronic digital computers (SC IV)
Electronic
digital computers with a composite theoretical performance (CTP) of 12.5
million theoretical operations per second (Mtops) or greater
except:
computers
essential for medical applications and incorporated in equipment or systems
designed or modified for identifiable and dedicated medical applications.
79.
Electronic equipment for time delay generation or time interval measurement,
as follows:
79.1. Digital time delay generators with a resolution of 50
nanoseconds or less over time intervals of 1 microsecond or greater;
79.2.
Multi-channel (three or more) or modular time interval meter
and chronometry equipment with time resolution less than 50 nanoseconds
over time ranges greater than 1 microsecond.
80.
Oscilloscopes
Oscilloscopes
and transient recorders as follows; and specially designed components
therefor:
80.1. Non-modular analog oscilloscopes having a bandwidth
of 1 GHz or greater;
80.2.
Modular analog oscilloscope systems having either of the
following characteristics;
(a) A mainframe with a bandwidth of 1 GHz or greater;
or
(b)
Plug-in modules with an individual bandwidth of 4 GHz
or greater.
80.3.
Analog sampling oscilloscopes for the analysis of recurring
phenomena with an effective bandwidth greater than 4 GHz;
80.4.
Digital oscilloscopes and transient recorders, using analog-to
digital conversion techniques, capable of storing transients by sequentially
sampling single-shot inputs at successive intervals of less than 1 Ns
(greater than 1 giga-sample per second), digitizing to 8 bits or greater
resolution and storing 256 or more samples.
NOTE
1:
Specially designed components for analog oscilloscopes, are: Plug-in
units; External amplifiers; Pre-amplifiers; Sampling devices; and
Cathode ray tubes;
NOTE
2:
"Bandwidth" is defined as the band of frequencies over which the deflection
on the cathode ray tube does not fall below 70.7% of that at the maximum
point measured with a constant input voltage to the oscilloscope amplifier.
81.
High-speed pulse generators
High-speed
pulse generators with output voltages greater than 6 V into a less than
55-ohm resistive load, and with pulse transition times less than 500 ps
(defined as the time interval between 10% and 90% voltage amplitude).
82.
Pulse amplifiers
Pulse
amplifiers with gain greater than 6 decibels and with a baseband bandwidth
greater than 500 megahertz (having the low frequency half-power point
at less than 1 MHz and the high frequency half-powered point greater than
500 MHz) and output voltage greater than 2 volts into 55 ohms or less
(this corresponds to an output greater than 16 dBm in a 50 ohm system).
83.
Photomultiplier tubes
Photomultiplier
tubes,with the following characteristics; a photocathode area of greater
than 20 cm2; and an anode pulse rise time of less than 1 Ns
84.
Frequency changers
Frequency
changers (also known as converters or invertors), other than those specified
in item 23.4, having all of the following characteristics:
(a) A multiphase output capable of providing a power of 40W
or more;
(b)
Capable of operating in the frequency range between 600 and
2000 Hz;
(c)
Total harmonic distortion below 10%; and
(d)
Frequency control better than 0.1%.
DETAILED
TABLE OF CONTENTS
GENERAL
NOTE...........................................................................................
i
ANNEX
3
Nuclear materials
1.
Source and special fissionable material......................................................2
Non-nuclear
materials
2.
Zirconium (SC IV).........................................................................................2
3.
Aluminum alloys...........................................................................................3
4.
Fibrous or filamentary materials (SC IV)....................................................3
5.
* Maraging steel (SC IV).............................................................................3
6.
Titanium........................................................................................................4
7.
Chlorine trifluoride (SC IV).........................................................................4
8.
* Fast-reacting ion-exchange resins/adsorbents.........................................4
9.
Beryllium (SC IV) ........................................................................................4
10.
Calcium ......................................................................................................4
11.
Magnesium (SC IV) ..................................................................................4
12.
Tantalum (SC IV) ......................................................................................4
13.
Tungsten (SC IV) ......................................................................................5
14.
Hafnium .....................................................................................................5
15.
Boron .........................................................................................................5
16.
Bismuth .....................................................................................................5
17.
Lithium ......................................................................................................5
18.
*Helium-3.................................................................................................
5
19.
Tritium 5
20.
Deuterium and heavy water.....................................................................6
21.
Nuclear grade graphite............................................................................
6
*
Plants for the separation of isotopes of uranium and equipment, other
than analytical instruments, specially designed or prepared therefor
22.
*Gas centrifuges and assemblies and components specially designed or prepared
for use in gas centrifuges.............................................................
6
23.
*Specially designed or prepared auxiliary systems, equipment and, components
for gas centrifuge enrichment plants......................................
9
24.
*Specially designed or prepared assemblies and components for use in gaseous
diffusion enrichment...................................................................
11
25.
*Specially designed or prepared auxiliary systems, equipment and components
for use in gaseous diffusion enrichment..............................
12
26.
*Specially designed or prepared systems, equipment and components for
use in aerodynamic enrichment plants...............................................
14
27.
*Specially designed or prepared systems, equipment and components for
use in chemical exchange or ion exchange enrichment plants.......... 17
28.
*Specially designed or prepared systems, equipment and components for
use in laser based enrichment plants..................................................
20
29.
* Systems, equipment, and components for use in plasma separation enrichment
plants......................................................................................
25
30.
* Systems, equipment and components for use in electromagnetic enrichment
plants......................................................................................
27
Analytical
instruments and process control systems used in uranium enrichment
31.
Mass spectrometers............................................................................
28
32.
Instrumentation and process control systems for use in enrichment (SC
IV) ..............................................................................................................
29
33.
* Software specially designed for the control of uranium enrichment plant
or facilities.........................................................................................
29
Other
isotope separation plants
34.
Plants for the production of heavy water, deuterium and deuterium compounds..................................................................................................
29
35.
*Plants and specially designed equipment for the separation of lithium-6
....................................................................................................................
32
36.
*Facilities or plants for the production, recovery, extraction, concentration,
or handling of tritium, and equipment and materials therefor ....................................................................................................................
32
Plants
and equipment for the conversion of uranium
37.
Specially designed or prepared systems for the conversion of uranium ore
concentrates to U03 ..........................................................................
33
38.
* Specially designed or prepared systems for the conversion of UO3
to UF6 ..........................................................................................................
33
39.
Specially designed or prepared systems for the conversion of UO3
to UO2 ..........................................................................................................
33
40.
Specially designed or prepared systems for the conversion of UO2
to UF4 ..........................................................................................................
34
41.
* Specially designed or prepared systems for the conversion of UF4
to UF6 ..........................................................................................................
34
42.
Specially designed or prepared systems for the conversion of UF4
to U metal ........................................................................................................
34
43.
* Specially designed or prepared systems for the conversion of UF6
to UO2..........................................................................................................
34
44.
* Specially designed or prepared systems for the conversion of UF6
to UF4 ..........................................................................................................
34
45.
* Specially designed or prepared systems for the conversion of UO2
to UCl4. ........................................................................................................
34
46.
Electrolytic cells for fluorine production with a production capacity
greater than 250 grams of fluorine per hour and specially designed parts
and accessories therefor (SC II) ............................................................
34
Nuclear
reactors and equipment therefor
47.
Complete nuclear reactors ..................................................................................................................
35
Nuclear
fuel fabrication plants
48. Plants for the fabrication of fuel elements...................................................................................................
36
Reprocessing
technology and equipment therefor
49. *Plants and equipment for the reprocessing of irradiated fuel elements..................
37
Industrial
equipment and machine tools
50.
*Rotor fabrication and assembly equipment and bellows forming mandrels
and dies ....................................................................................
40
51.
*Centrifugal balancing machines ......................................................
41
52.
*Filament winding machines (SC IV) ................................................
41
53.
Spin-forming and flow-forming machines (SC IV)............................
42
54.
Dimensional inspection machines.....................................................
42
55.
Electron beam welding machines.......................................................
44
56.
Plasma spray systems.......................................................................
44
57.
Oxidation furnaces.............................................................................
44
58.
High temperature furnaces................................................................
45
59.
Isostatic presses (cold and hot) (SC IV)...........................................
45
60. Machine tools (SC IV).......................................................................
45
61.
Vibration test equipment (SC IV)......................................................
46
62.
"Robots" and "end-effectors" and specially designed controllers and software
therefor.....................................................................................
46
Implosion
systems development equipment
63. *Specialized equipment for hydrodynamic experiments..................
47
64. Flash X-ray equipment.......................................................................
47
65.
*Gun systems.....................................................................................
48
66.
*Mechanical rotating mirror cameras...............................................
48
67.
*Electronic streak and framing cameras and tubes..........................
48
68.
*Computer codes for nuclear explosives...........................................
48
69.
Detonators and multi-point initiator systems....................................
49
70.
*Explosive lenses...............................................................................
49
71.
* Firing sets and equivalent high-current pulse generators (for controlled
detonators)..............................................................................
49
72.
Switching devices...............................................................................
50
73.
Capacitors..........................................................................................
50
74.
High explosives (SC IV)....................................................................
51
Other
equipment
75.
Crucibles..............................................................................................
51
76.
Alpha sources.......................................................................................
52
77.
Neutron generator systems.................................................................
52
78.
Electronic digital computers (SC IV)..................................................
52
79.
Electronic equipment for time delay generation or time interval measurement.............................................................................................
52
80.
Oscilloscopes.......................................................................................
53
81.
High-speed pulse generators..............................................................
53
82.
Pulse amplifiers...................................................................................
53
83.
Photomultiplier tubes..........................................................................
54
84.
Frequency changers............................................................................
54
APPENDIX
TO ANNEX 3.......................................................................
55
|